Image-Based Motion Compensation for High-Resolution Extremities Cone-Beam CT.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Evaluation of Motion Artifact Correction Technique for Cone-Beam Computed Tomography Image Considering Blood Vessel Geometry.Journal of clinical medicine · 2024Article
- Science and practice of imaging physics through 50 years of SPIE Medical Imaging conferences.Journal of medical imaging (Bellingham, Wash.) · 2022Article
- Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.Medical physics · 2018Article
- The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.Medical physics · 2017Article
- Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion.Physics in medicine and biology · 2017Article
- High-resolution extremity cone-beam CT with a CMOS detector: Task-based optimization of scintillator thickness.Proceedings of SPIE--the International Society for Optical Engineering · 2017Article
- Deformable Known Component Model-Based Reconstruction for Coronary CT Angiography.Proceedings of SPIE--the International Society for Optical Engineering · 2017Article
- Targeted Deformable Motion Compensation for Vascular Interventional Cone-Beam CT Imaging.Proceedings of SPIE--the International Society for Optical EngineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeCone-beam CT (CBCT) of the extremities provides high spatial resolution, but its quantitative accuracy may be challenged by involuntary sub-mm patient motion that cannot be eliminated with simple means of external immobilization. We investigate a two-step iterative motion compensation based on a multi-component metric of image sharpness.
methodsMotion is considered with respect to locally rigid motion within a particular region of interest, and the method supports application to multiple locally rigid regions. Motion is estimated by maximizing a cost function with three components: a gradient metric encouraging image sharpness, an entropy term that favors high contrast and penalizes streaks, and a penalty term encouraging smooth motion. Motion compensation involved initial coarse estimation of gross motion followed by estimation of fine-scale displacements using high resolution reconstructions. The method was evaluated in simulations with synthetic motion (1-4 mm) applied to a wrist volume obtained on a CMOS-based CBCT testbench. Structural similarity index (SSIM) quantified the agreement between motion-compensated and static data. The algorithm was also tested on a motion contaminated patient scan from dedicated extremities CBCT.
resultsExcellent correction was achieved for the investigated range of displacements, indicated by good visual agreement with the static data. 10-15% improvement in SSIM was attained for 2-4 mm motions. The compensation was robust against increasing motion (4% decrease in SSIM across the investigated range, compared to 14% with no compensation). Consistent performance was achieved across a range of noise levels. Significant mitigation of artifacts was shown in patient data.
conclusionThe results indicate feasibility of image-based motion correction in extremities CBCT without the need for a priori motion models, external trackers, or fiducials.