ArticleMagnetic resonance in medicine2017
Rapid measurement of brain macromolecular proton fraction with transient saturation transfer MRI.
Article in Magnetic resonance in medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed.
- Magnetization transfer weighted EPI facilitates cortical depth determination in native fMRI space.NeuroImage · 2021Trial
- Rapid Tissue-CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling.Magnetic resonance in medicine · 2026Article
- Resolving mesoscale brainstem-prefrontal-striatal pathways underlying decisions upon salient events using submillimeter-resolution fMRI.Nature communications · 2026Article
- Multi-contrast dual-resolution UTE for myelin fraction mapping and structural imaging.Magma (New York, N.Y.) · 2026Article
- Quantitative magnetic resonance imaging in Alzheimer's disease: a narrative review.Quantitative imaging in medicine and surgery · 2025Review
- An unconstrained four pool model analysis of proton relaxation and magnetization transfer in ex vivo white matter.Scientific reports · 2025Article
- Blood nulling versus tissue suppression: Enhancing integrated VASO and perfusion (VAPER) contrast for laminar fMRI.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Compartmental anisotropy of filtered exchange imaging (FEXI) in human white matter: What is happening in FEXI?Magnetic resonance in medicine · 2024Article
- Improving laminar fMRI specificity by reducing macrovascular bias revealed by respiration effects.Imaging neuroscience (Cambridge, Mass.) · 2024Article
- Unlocking near-whole-brain, layer-specific functional connectivity with 3D VAPER fMRI.Imaging neuroscience (Cambridge, Mass.) · 2024Article
- Creatine mapping of the brain at 3T by CEST MRI.Magnetic resonance in medicine · 2024Article
- Exploring methodological frontiers in laminar fMRI.Psychoradiology · 2024Review
- Nonaqueous magnetization following adiabatic and selective pulses in brain: T1 and cross-relaxation dynamics.NMR in biomedicine · 2023Article
- Combining arterial blood contrast with BOLD increases fMRI intracortical contrast.Human brain mapping · 2023Article
- Evaluating brain damage in multiple sclerosis with simultaneous multi-angular-relaxometry of tissue.Annals of clinical and translational neurology · 2022Article
- An end-to-end AI-based framework for automated discovery of rapid CEST/MT MRI acquisition protocols and molecular parameter quantification (AutoCEST).Magnetic resonance in medicine · 2022Article
- Macromolecular Proton Fraction as a Myelin Biomarker: Principles, Validation, and Applications.Frontiers in neuroscience · 2022Review
- Data-Driven Retrospective Correction of BIEEE transactions on medical imaging · 2021Article
- Topographical and laminar distribution of audiovisual processing within human planum temporale.Progress in neurobiology · 2021Article
- Unraveling the contributions to the neuromelanin-MRI contrast.Brain structure & function · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeTo develop an efficient MRI approach to estimate the nonwater proton fraction (f) in human brain.
methodsWe implement a brief, efficient magnetization transfer (MT) pulse that selectively saturates the magnetization of the (semi-) solid protons, and monitor the transfer of this saturation to the water protons as a function of delay after saturation.
resultsAnalysis of the transient MT effect with two-pool model allowed robust extraction of f at both 3 and 7 T. This required estimating the longitudinal relaxation rate constant (R
conclusionExperiments performed on human brain in vivo at 3 and 7 T demonstrate the ability of the method to robustly determine f in a scan time of approximately 5 min. Magn Reson Med 77:2174-2185, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.