ArticleJournal of surgical case reports2016
Small bowel obstruction caused by self-anchoring suture used for peritoneal closure following robotic inguinal hernia repair.
Article in Journal of surgical case reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.
- Intestinal erosions following inguinal hernia repair: a systematic review.Hernia : the journal of hernias and abdominal wall surgery · 2021Pooled it
- Nonclosure of the Peritoneum during Appendectomy May Cause Less Postoperative Pain: A Randomized, Double-Blind Study.Pain research & management · 2019Trial
- TITANIUM CLIPS FOR CLOSURE OF THE PERITONEAL FLAP DURING LAPAROSCOPIC INGUINAL HERNIA REPAIR.Arquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery · 2022Article
- Recurrent abdominal pain due to small bowel volvulus after transabdominal preperitoneal hernioplasty: A case report and review of literature.World journal of clinical cases · 2021Article
- Peritoneal pocket hernia: A distinct cause of early postoperative small bowel obstruction and strangulation: A report of two cases following robotic herniorrhaphy.Journal of minimal access surgeryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Laparoscopic inguinal herniorraphy is a commonly performed procedure given the reported decrease in pain and earlier return to activity when compared with the open approach. Moreover, robotic assistance offers the operating surgeon considerable ergonomic advantages, making it an attractive alternative to conventional laparoscopic herniorraphy. Robotic herniorraphy utilizes the transabdominal preperitoneal approach where following repair peritoneal closure is necessary to avoid mesh exposure to the viscera. Self-anchoring sutures are frequently used to this end given the ease of use and knotless application. We present an unusual case of post-operative small bowel obstruction following robotic inguinal hernia repair caused by the self-anchoring suture used for peritoneal closure. This patient presented 3 days post-procedure with symptoms and cross-sectional imaging indicative of small bowel obstruction with a clear transition point. Underwent laparoscopic lysis of a single adhesive band originating from the loose intraperitoneal end of the suture leading to resolution of symptoms.