ArticleClinical orthopaedics and related research2016
High Risk of Surgical Glove Perforation From Surgical Rotatory Instruments.
Article in Clinical orthopaedics and related research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05928663 (The Effect on Puncture of the Use of Double Gloves in Orthopedic Surgery), which is not on this map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Effect on Puncture of the Use of Double Gloves in Orthopedic Surgery
Who cites it
10 citing papers in PubMed, 42 citations in OpenAlex.
- Higher rate of undetected intraoperative damage of latex-free surgical gloves worn by scrub nurses.Perioperative medicine (London, England) · 2025Article
- Article
- Surgical glove perforation during intramedullary nailing of intertrochanteric fractures.Scientific reports · 2025Article
- A randomized trial comparing the intraoperative durability of double-gloving with Biogel® surgical gloves to 3 comparators.Antimicrobial stewardship & healthcare epidemiology : ASHE · 2024Article
- Assessment of glove integrity across various dental specialties in a dental school setting.Frontiers in oral health · 2024Article
- Wearable Natural Rubber Latex Gloves with Curcumin for Torn Glove Detection in Clinical Settings.Polymers · 2022Article
- Intraoperative damage to surgical gloves during various operations on the musculoskeletal system: a multicenter study.Archives of orthopaedic and trauma surgery · 2022Article
- Is Single Gloving Still Acceptable? Investigation and Evaluation of Damages on Sterile Latex Gloves in General Surgery.Journal of clinical medicine · 2021Article
- Damages with High Consequences: Analysis of Perforations in Surgical Latex Operation Gloves from Orthopedic Surgeries.European journal of microbiology & immunology · 2018Article
- Evaluation of Surgical Glove Perforation and Sharps Injury in Oral and Maxillofacial Surgery.Journal of the West African College of SurgeonsArticle
Corrections and comments
- Commented on byCORR Insights2016
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSurgical gloves can be damaged during the course of a procedure, which can place the surgeon and patient at risk. Glove perforation may not always be readily apparent, and determining the risk factors for glove perforation can aid the surgeon in deciding when a glove change is advisable. Time of wear and needle sticks have been well studied; however, other mechanisms including mechanical stress from surgical equipment have had limited evaluation to date. QUESTIONS/PURPOSES: We evaluated the risk of glove perforation in gloves that were caught in a surgical rotatory device (such as drills and reamers). The aims of our study were (1) to determine the percentage of undetected microperforations after entanglement on a rotatory tool during orthopaedic procedures, (2) to determine which kinds of rotatory devices most commonly cause such microperforations, and (3) to assess whether time of wear had an effect on the risk of perforation.
methodsFrom July 2014 to September 2015, 33 gloves were obtained from all orthopaedic subspecialties at our Level I trauma center if they were caught in a rotatory device greater than one revolution. Time of glove wear and location of the glove that was caught in a rotatory device were recorded. After an evaluation for macroperforations (≥ 5 mm), the gloves were evaluated for microperforations (< 5 mm) via the American Society for Testing and Materials (ASTM) one-liter load test. Time of wear was compared among gloves with macroperforations, microperforations, and no perforations.
resultsThe 33 gloves obtained came from 33 procedures. Seventeen of 33 (52 %) gloves had perforations. Seven of the 17 perforated gloves had macroperforations while 10 had microperforations. Eleven of 33 entanglements were caught by drills, nine by reamers, eight by K-wires, and the remaining five gloves were caught by various other instruments. Eight of 17 perforations were caused by drills, three by reamers, three by K-wires, and three by various other instruments. The average time of wear was 58 minutes which did not differ with pattern of glove damage.
conclusionSurgical gloves caught in a rotatory power instrument are likely to have been perforated, regardless of the amount of time that they had been worn. Visual inspection appears to be an inadequate test of glove integrity. When a glove becomes entangled in a rotary instrument such as a drill, pin, or reamer, a surgeon should change the gloves regardless of whether he or she believes a perforation is present. LEVEL OF EVIDENCE: Level IV, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.