Evidence map›Paper›PMID 27334008›Full record

ArticleLa Radiologia medica2016

Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience.

Dechao Jiao, Kai Huang, Gang Wu, Yanli Wang, Xinwei Han

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Dechao JiaoDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Kai HuangDepartment of Oncology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Gang WuDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Yanli WangDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Xinwei HanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China. 13592583911@163.com.
First Affiliated Hospital of Zhengzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to evaluate the usefulness of flat detector cone-beam CT-guided CBCT percutaneous needle biopsy (PNB) of mediastinal lesions.

methodsA total of 100 patients with 100 solid mediastinal lesions were retrospectively enrolled to undergo percutaneous needle biopsy (PNB) procedures. The mean diameter of lesions was 4.4 ± 1.8 cm (range 1.8-9.0 cm). The needle path was carefully planned and calculated on the CBCT virtual navigation guidance system, which acquired 3D CT-like cross-sectional images. Diagnostic performance, procedure details, complication rate, and patient radiation exposure were investigated.

resultsThe technical success rate of PNB under CBCT virtual navigation system was 100 % (100/100). The sensitivity, specificity, and accuracy of PNB of small nodules under iGuide CBCT virtual navigation guidance were 95.1 % (79/83), 100 % (12/12), and 95.7 % (91/95), respectively. The number of biopsies and CBCT acquisitions were 2.6 ± 1.2 (range 1-6) and 3.0 ± 1.1 (range 2-8), respectively. Complications occurred in five (5.0 %) cases. The mean total procedure time was 11.70 ± 3.44 min (range 6-27 min), resulting in a mean exposure dose of 9.7 ± 4.3 mSv.

conclusionFlat detector cone-beam CT-guided PNB is an accurate and safe diagnostic method for mediastinal lesions.

Indexed as

AdultAgedAged, 80 and overBiopsy, NeedleCone-Beam Computed TomographyFemaleHumansImage-Guided BiopsyMaleMediastinal DiseasesMiddle AgedRadiation DosageRadiography, InterventionalRetrospective StudiesSensitivity and SpecificityBiopsyComputer application-3DInterventionalMediastinal lesion

Identifiers

PMID27334008
OpenAlexW2464498687

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.