Evidence map›Paper›PMID 27324964›Full record

ReviewDer Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft2016

[Intraoperative optical coherence tomography for examination of newborns and infants under general anesthesia].

S Siebelmann, B Bachmann, A Lappas, T Dietlein, P Steven, C Cursiefen

Abstract readReview
PubMed Publisher
In one paragraph

Review in Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. [Surgical treatment options for congenital/infantile corneal opacities and anterior segment dysgenesis].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2022
    Review
  4. [Diagnostics, clinical aspects and genetics of congenital corneal opacities].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2022
    Review
  5. Review
  6. [Long-term prognosis of Peters anomaly].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

S SiebelmannZentrum für Augenheilkunde, Uniklinik Köln, Kerpener Str. 62, 50924, Köln, Deutschland. Sebastian.Siebelmann@uk-koeln.de.
B BachmannZentrum für Augenheilkunde, Uniklinik Köln, Kerpener Str. 62, 50924, Köln, Deutschland.
A LappasZentrum für Augenheilkunde, Uniklinik Köln, Kerpener Str. 62, 50924, Köln, Deutschland.
T DietleinZentrum für Augenheilkunde, Uniklinik Köln, Kerpener Str. 62, 50924, Köln, Deutschland.
P StevenZentrum für Augenheilkunde, Uniklinik Köln, Kerpener Str. 62, 50924, Köln, Deutschland.
C CursiefenZentrum für Augenheilkunde, Uniklinik Köln, Kerpener Str. 62, 50924, Köln, Deutschland.
University Hospital Cologne · DECologne Excellence Cluster on Cellular Stress Responses in Aging Associated Diseases · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExamination of newborn and children under general anesthesia is essential to prevent amblyopia and blindness; however, the validity was often limited due to a lack of state of the art diagnostic tools in the intraoperative set-up, e. g. optical coherence tomography (OCT). Since OCT devices have been integrated into surgical microscopes, this technique is also available for examination with patients under general anesthesia.

objectiveTo give an overview about the possibilities of intraoperative OCT (iOCT) during examination of newborn and infant children under general anesthesia. MATERIAL AND

methodsAnalysis of recent literature (PubMed) and initial experiences at the Center for Ophthalmology of the University Hospital of Cologne.

resultsThe use of iOCT enables real-time high-resolution imaging during examinations of children under general anesthesia. All relevant structures of the anterior eye segment (including cornea, lens, chamber angle and iris) can be visualized. Especially when the anterior chamber view is limited due to corneal opacifications, iOCT can deliver important information in addition to that obtained using a surgical microscope. This information is important for the further therapy of the patients.

conclusionOnline iOCT is a useful extension of the normal surgical microscope, especially for examination of children under general anesthesia and limited view into the anterior chamber. In our experience it also makes sense to transfer this technique to anomalies of the posterior pole because high-resolution imaging of the macula and optic nerve head is possible.

Indexed as

Anesthesia, GeneralEvidence-Based MedicineEye DiseasesFemaleHumansImage EnhancementInfantInfant, NewbornInfant, Newborn, DiseasesMaleMonitoring, IntraoperativeOphthalmologic Surgical ProceduresSurgery, Computer-AssistedTomography, Optical CoherenceTreatment OutcomeAmblyopiaAnesthesia, generalAnterior chamberMicroscopeSurgical procedures

Identifiers

PMID27324964
OpenAlexW2469042306

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked