Evidence map›Paper›PMID 27314506›Full record

ArticleMedical & biological engineering & computing2017

Geometry reconstruction method for patient-specific finite element models for the assessment of tibia fracture risk in osteogenesis imperfecta.

Christiane Caouette, Nicole Ikin, Isabelle Villemure, Pierre-Jean Arnoux, Frank Rauch, Carl-Éric Aubin

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Fast in silico assessment of physical stress for peripheral nerves.Medical & biological engineering & computing · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Christiane CaouetteCanada Research Chair in Orthopedic Engineering, Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, QC, H3C 3A7, Canada.
Nicole IkinCanada Research Chair in Orthopedic Engineering, Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, QC, H3C 3A7, Canada.
Isabelle VillemureSainte-Justine University Hospital Center, Montréal, QC, Canada.
Pierre-Jean ArnouxIFSTTAR, Aix-Marseille University, Marseille, France.
Frank RauchSainte-Justine University Hospital Center, Montréal, QC, Canada.
Carl-Éric AubinCanada Research Chair in Orthopedic Engineering, Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, QC, H3C 3A7, Canada. carl-eric.aubin@polymtl.ca.
Centre Hospitalier Universitaire Sainte-Justine · CAAix-Marseille Université · FRPolytechnique Montréal · CAShriners Hospitals for Children - Canada · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Lower limb deformation in children with osteogenesis imperfecta (OI) impairs ambulation and may lead to fracture. Corrective surgery is based on empirical assessment criteria. The objective was to develop a reconstruction method of the tibia for OI patients that could be used as input of a comprehensive finite element model to assess fracture risks. Data were obtained from three children with OI and tibia deformities. Four pQCT scans were registered to biplanar radiographs, and a template mesh was deformed to fit the bone outline. Cortical bone thickness was computed. Sensitivity of the model to missing slices of pQCT was assessed by calculating maximal von Mises stress for a vertical hopping load case. Sensitivity of the model to ±5 % of cortical thickness measurements was assessed by calculating loads at fracture. Difference between the mesh contour and bone outline on the radiographs was below 1 mm. Removal of one pQCT slice increased maximal von Mises stress by up to 10 %. Simulated ±5 % variation of cortical bone thickness leads to variations of up to 4.1 % on predicted fracture loads. Using clinically available tibia imaging from children with OI, the developed reconstruction method allowed the building of patient-specific finite element models.

Indexed as

Models, AnatomicAdolescentChildFemaleFinite Element AnalysisHumansMaleOsteogenesis ImperfectaPrecision MedicineRisk AssessmentTibial FracturesFinite element modelingOsteogenesis imperfectaPatient-specific geometryTibia bowing

Identifiers

PMID27314506
OpenAlexW2421618603

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked