ArticleEuropean journal of nuclear medicine and molecular imaging2016
Fusion of freehand SPECT and ultrasound: First experience in preoperative localization of sentinel lymph nodes.
Article in European journal of nuclear medicine and molecular imaging, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 31 citations in OpenAlex.
- Gamma probe and ultrasound-guided fine needle aspiration cytology of the sentinel node (GULF) trial.European journal of nuclear medicine and molecular imaging · 2018Trial
- Simultaneous Identification of Tc-99m-Sestamibi-Positive Autonomous Thyroid Adenoma and Adjacent F-18-Ethylcholine-Positive Parathyroid Adenoma in Patient with Graves' Disease Using Real-Time Ultrasound Fusion Imaging.Diagnostics (Basel, Switzerland) · 2025Article
- Molecular image-guided surgery in gynaecological cancer: where do we stand?European journal of nuclear medicine and molecular imaging · 2024Review
- Feasibility and Performance of Free-Hand Single-Photon Computed Tomography/Ultrasonography for Preoperative Parathyroid Adenoma Localization: A Pilot Study.Diagnostics (Basel, Switzerland) · 2023Article
- Study on intraoperative localization of sentinel lymph nodes using freehand SPECT in breast cancer patients.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2022Article
- The current status and future prospects for molecular imaging-guided precision surgery.Cancer imaging : the official publication of the International Cancer Imaging Society · 2022Review
- A Review of Nuclear Medicine Approaches in the Diagnosis and the Treatment of Gynecological Malignancies.Cancers · 2022Review
- How molecular imaging will enable robotic precision surgery : The role of artificial intelligence, augmented reality, and navigation.European journal of nuclear medicine and molecular imaging · 2021Review
- Lymphoscintigraphy and sentinel lymph node biopsy in vulvar carcinoma: update from a European expert panel.European journal of nuclear medicine and molecular imaging · 2020Review
- Data processing of 3D and 4D in-vivo electron paramagnetic resonance imaging co-registered with ultrasound. 3D printing as a registration tool.Computers & electrical engineering : an international journal · 2019Article
- SUPRA: open-source software-defined ultrasound processing for real-time applications : A 2D and 3D pipeline from beamforming to B-mode.International journal of computer assisted radiology and surgery · 2018Article
- Preoperative sentinel lymph node localization in vulvar cancer: preliminary experience with inguinal intradermal contrast-enhanced ultrasound.European radiology · 2018Article
- Article
- Observational
- Crossing technological frontiers in radioguided intervention.European journal of nuclear medicine and molecular imaging · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeRadioguided sentinel lymph node biopsy (SLNB) is the standard of care in breast cancer and melanoma. Additional preoperative Single-photon emission computed tomography (SPECT/CT) for improved anatomical co-registration of the SLNs causes additional radiation exposure and is time-consuming and expensive. The aim of this prospective study was to evaluate a novel approach involving real-time fusion of freehand SPECT (fhSPECT) and ultrasound (US) for anatomical co-registration of SLNs.
methodsFrom February 2015 to February 2016, 153 patients were included in this prospective study. All patients underwent lymphoscintigraphy according to practical guidelines and 151 (118 cases of breast cancer, 30 cutaneous malignancies, and three cases of vulvar cancer) of the 153 patients were additionally investigated with fhSPECT-US. FhSPECT connected to a hand-held gamma detector generates three-dimensional images of the radioactivity distribution in the scanned area. For co-registration and real-time fusion of fhSPECT and subsequently performed US, an infrared stereo tracking system was used.
resultsIn all patients an SLN was found on lymphoscintigraphy, and the fhSPECT detected corresponding hotspots in all but one patient. In 72 % of patients and 73 % of lymph node basins, real-time anatomical co-registration with US was feasible. The rate of success in achieving good co-registration increased from 60 to 75 % after training by a radiologist specialized in breast imaging. A higher co-registration rate (78 %) was observed in patients with only one SLN than in those with two SLNs (68 %) or three or more SLNs (0 %).
conclusionsReal-time fusion of fhSPECT and US for preoperative anatomical co-registration of SLNs is feasible. However, before this approach can completely replace preoperative lymphatic imaging, further technical developments are needed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials