Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2017
Conventional versus computer-navigated TKA: a prospective randomized study.
Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
28 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022Pooled it
- Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials.Journal of orthopaedic surgery and research · 2017Pooled it
- The effects of immediate programmed cryotherapy and continuous passive motion in patients after computer-assisted total knee arthroplasty: a prospective, randomized controlled trial.Journal of orthopaedic surgery and research · 2020Trial
- The Dark Side of Precision: Pin-Related Complications in Computer-Navigated and Robotic-Assisted Knee Arthroplasty.Journal of clinical medicine · 2026Review
- Concurrent validation of a novel intraoperative navigation platform for total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2026Article
- Technology in Total Hip Arthroplasty: Recent Advancements.Orthopedic reviews · 2026Article
- Comparison of the accuracy and efficacy of different assistive techniques in primary total knee arthroplasty: A network meta-analysis.Journal of experimental orthopaedics · 2024Article
- Influence of posterior tibial slope on postoperative outcomes after postero-stabilized and condylar-stabilized total knee arthroplasty.Musculoskeletal surgery · 2023Article
- Customized-individually-made origin® implants in total knee arthroplasty allow a reliable solution for accurate reproduction of planned implant positioning.Journal of experimental orthopaedics · 2023Article
- No Difference in Clinical Outcomes and Survivorship for Robotic, Navigational, and Conventional Primary Total Knee Arthroplasty with a Minimum Follow-up of 10 Years.Clinics in orthopedic surgery · 2023Article
- Funding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest.Arthroplasty (London, England) · 2022Article
- Satisfactory mid- to long-term outcomes of TKA aligned using conventional instrumentation for flexion gap balancing with minimal soft tissue release.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- After 25 years of computer-navigated total knee arthroplasty, where do we stand today?Arthroplasty (London, England) · 2021Review
- Efficacy Analysis of Selection of Distal Reference Point for Tibial Coronal Plane Osteotomy during Total Knee Arthroplasty: A Literature Review.Orthopaedic surgery · 2021Review
- No influence of obesity on mid-term clinical, functional, and radiological results after computer-navigated total knee arthroplasty using a gap balancing technique.Journal of clinical orthopaedics and trauma · 2021Article
- Navigation-assisted anchor insertion in shoulder arthroscopy: a validity study.BMC musculoskeletal disorders · 2020Article
- A visual odometry base-tracking system for intraoperative C-arm guidance.International journal of computer assisted radiology and surgery · 2020Article
- Computer and robotic - assisted total knee arthroplasty: a review of outcomes.Journal of experimental orthopaedics · 2020Review
- Computer-navigated versus conventional total knee arthroplasty: A randomized controlled trial protocol in China.Medicine · 2020Article
- An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design.BMC musculoskeletal disorders · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to assess the midterm results of total knee arthroplasty (TKA) implanted with a specific computer navigation system in a group of patients (NAV) and to assess the same prosthesis implanted with the conventional technique in another group (CON); we hypothesized that computer navigation surgery would improve implant alignment, functional scores and survival of the implant compared to the conventional technique.
methodsFrom 2008 to 2009, 225 patients were enrolled in the study and randomly assigned in CON and NAV groups; 240 consecutive mobile-bearing ultra-congruent score (Amplitude, Valence, France) TKAs were performed by a single surgeon, 117 using the conventional method and 123 using the computer-navigated approach. Clinical outcome assessment was based on the Knee Society Score (KSS), the Hospital for Special Surgery Knee Score and the Western Ontario Mac Master University Index score. Component survival was calculated by Kaplan-Meier analysis.
resultsMedian follow-up was 6.4 years (range 6-7 years). Two patients were lost to follow-up. No differences were seen between the two groups in age, sex, BMI and side of implantation. Three patients of CON group referred feelings of instability during walking, but clinical tests were all negative. NAV group showed statistical significant better KSS Score and wider ROM and fewer outliers from neutral mechanical axis, lateral distal femoral angle, medial proximal tibial angle and tibial slope in post-operative radiographic assessment. There was one case of early post-operative superficial infection (caused by Staph. Aureus) successfully treated with antibiotics. No mechanical loosening, mobile-bearing dislocation or patellofemoral complication was seen. At 7 years of follow-up, component survival in relation to the risk of aseptic loosening or other complications was 100 %. There were no implant revisions.
conclusionThis study demonstrates superior accuracy in implant positioning and statistical significant better functional outcomes of computer-navigated TKA. Computer navigation for TKAs should be used routinely in primary implants. LEVEL OF EVIDENCE: II.
Indexed as
Identifiers
27306985What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.