ArticleJournal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine2016
Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.
Article in Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Article
- Efficacy of nasal masks versus nasal pillows masks during continuous positive airway pressure titration for patients with obstructive sleep apnea.Sleep & breathing = Schlaf & Atmung · 2021Article
- Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2020Article
- Influence of interface and position on upper airway collapsibility assessed by negative expiratory pressure.Sleep & breathing = Schlaf & Atmung · 2017Article
- Retrospective: When Were Oronasal Masks First Used to Treat Obstructive Sleep Apnea?Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2017Article
- CPAP Use: Unmasking the Truth about Interface.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2016Article
- Practice recommendations for the role of physiotherapy in the management of sleep disorders: the 2022 Brazilian Sleep Association Guidelines.Sleep science (Sao Paulo, Brazil)Review
- Comparing CPAP masks during initial titration for Obstructive Sleep Apnea Syndrome: one-year experience.Brazilian journal of otorhinolaryngologyArticle
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
STUDY
objectivesThe choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask.
methodsWe retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors.
resultsThe 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms.
conclusionsIf patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. COMMENTARY: A commentary on this article appears in this issue on page 1209.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.