ArticleJournal of biomedical optics2016
Dual-band optical coherence tomography using a single supercontinuum laser source.
Article in Journal of biomedical optics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed.
- Ultrabroadband OCT for simultaneous visible and near-infrared light imaging of the mouse retina.Biomedical optics express · 2026Article
- Visible Light Optical Coherence Tomography: Technology and Biomedical Applications.Bioengineering (Basel, Switzerland) · 2025Review
- Visible-light optical coherence tomography and its applications.Neurophotonics · 2025Review
- In vivo imaging of the inner retinal layer structure in mice after eye-opening using visible-light optical coherence tomography.Experimental eye research · 2021Article
- Optical Coherence Tomography and Glaucoma.Annual review of vision science · 2021Review
- Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser.Biomedical optics express · 2019Article
- Designing visible-light optical coherence tomography towards clinics.Quantitative imaging in medicine and surgery · 2019Article
- Spectral contrast optical coherence tomography angiography enables single-scan vessel imaging.Light, science & applications · 2019Article
- Scattering-Angle-Resolved Optical Coherence Tomography of a Hypoxic Mouse Retina Model.Journal of experimental neuroscience · 2019Article
- Buffer-averaging super-continuum source based spectral domain optical coherence tomography for high speed imaging.Biomedical optics express · 2018Article
- Spatially confined quantification of bilirubin concentrations by spectroscopic visible-light optical coherence tomography.Biomedical optics express · 2018Article
- Visible-light optical coherence tomography oximetry based on circumpapillary scan and graph-search segmentation.Biomedical optics express · 2018Article
- Fiber-based visible and near infrared optical coherence tomography (vnOCT) enables quantitative elastic light scattering spectroscopy in human retina.Biomedical optics express · 2018Article
- Automated spectroscopic retinal oximetry with visible-light optical coherence tomography.Biomedical optics express · 2018Article
- In vivo broadband visible light optical coherence tomography probe enables inverse spectroscopic analysis.Optics letters · 2018Article
- Visible-light optical coherence tomography: a review.Journal of biomedical optics · 2017Review
- OCT angiography and visible-light OCT in diabetic retinopathy.Vision research · 2017Review
- Angiographic and structural imaging using high axial resolution fiber-based visible-light OCT.Biomedical optics express · 2017Article
- Spectroscopic Doppler analysis for visible-light optical coherence tomography.Journal of biomedical optics · 2017Article
- Wavelength-dependent optical properties of melanosomes in retinal pigmented epithelium and their changes with melanin bleaching: a numerical study.Biomedical optics express · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
We developed a simultaneous visible-light (Vis) and near-infrared (NIR) dual-band optical coherence tomography (OCT) system using a single supercontinuum laser source. The goal was to benchmark our newly developed Vis-OCT against the well-developed NIR-OCT. The Vis-OCT subsystem operated at 91 nm full-width-at-half-maximum (FWHM) bandwidth centered at 566 nm; the NIR-OCT subsystem operated at 93 nm FWHM bandwidth centered at 841 nm. The axial resolutions were 1.8 and 4.4 μm in air for the Vis- and NIR-OCT subsystems, respectively. We compared the respective performances, including anatomical imaging, angiography, absolute retinal blood flow measurements, and spectroscopic analysis for retinal blood oxygen saturation (sO2), between the two subsystems in rodents in vivo. While demonstrating minor discrepancies related to operation wavelengths, both subsystems showed comparable performances in the first three tests. However, we were only able to retrieve sO2 using the Vis-OCT subsystem.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.