Evidence map›Paper›PMID 27300653›Full record

ArticleJournal of medical ultrasonics (2001)2016

Synthetic aperture ultrasound imaging with a ring transducer array: preliminary ex vivo results.

Xiaolei Qu, Takashi Azuma, Takeshi Yogi, Shiho Azuma, Hideki Takeuchi, Satoshi Tamano, Shu Takagi

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 39 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Xiaolei QuGraduate School of Engineering, The University of Tokyo, Bunkyo, Tokyo, 113-8656, Japan.
Takashi AzumaGraduate School of Engineering, The University of Tokyo, Bunkyo, Tokyo, 113-8656, Japan. azuma@fel.t.u-tokyo.ac.jp.
Takeshi YogiGraduate School of Engineering, The University of Tokyo, Bunkyo, Tokyo, 113-8656, Japan.
Shiho AzumaGraduate School of Engineering, The University of Tokyo, Bunkyo, Tokyo, 113-8656, Japan.
Hideki TakeuchiGraduate School of Engineering, The University of Tokyo, Bunkyo, Tokyo, 113-8656, Japan.
Satoshi TamanoDepartment of Biomedical Engineering, Tohoku University, Sendai, 980-8579, Japan.
Shu TakagiGraduate School of Engineering, The University of Tokyo, Bunkyo, Tokyo, 113-8656, Japan.
The University of Tokyo · JPTohoku University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe conventional medical ultrasound imaging has a low lateral spatial resolution, and the image quality depends on the depth of the imaging location. To overcome these problems, this study presents a synthetic aperture (SA) ultrasound imaging method using a ring transducer array.

methodsAn experimental ring transducer array imaging system was constructed. The array was composed of 2048 transducer elements, and had a diameter of 200 mm and an inter-element pitch of 0.325 mm. The imaging object was placed in the center of the ring transducer array, which was immersed in water. SA ultrasound imaging was then employed to scan the object and reconstruct the reflection image.

resultsBoth wire phantom and ex vivo experiments were conducted. The proposed method was found to be capable of producing isotropic high-resolution images of the wire phantom. In addition, preliminary ex vivo experiments using porcine organs demonstrated the ability of the method to reconstruct high-quality images without any depth dependence.

conclusionThe proposed ring transducer array and SA ultrasound imaging method were shown to be capable of producing isotropic high-resolution images whose quality was independent of depth.

Indexed as

AnimalsEquipment DesignHeartKidneyPhantoms, ImagingSwineUltrasonographyWaterWaterRing transducerSynthetic aperture techniqueUltrasound computed tomographyUltrasound reflection image

Identifiers

PMID27300653
OpenAlexW2433344986

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.