ArticleJournal of thoracic disease2016
Successful extracorporeal membrane oxygenation (ECMO) support in two pediatric heart transplant patients with extreme donor/recipient size mismatch.
Article in Journal of thoracic disease, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Insights into the history and tendency of extracorporeal membrane oxygenation-supported pediatric organ transplantation: a bibliometric-based visual analysis.Annals of medicine and surgery (2012) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Here we report two cases of extracorporeal membrane oxygenation (ECMO) support in pediatric patients following orthotopic heart transplantation due to low cardiac output and inability to separate from cardiopulmonary bypass (CPB). Both patients had significant donor/recipient size mismatch: ratios were 0.71 and 1.73. Cannulation was via the right atrium to ascending aorta using Maquet ECMO kits to achieve veno-arterial ECMO (VA-ECMO) configuration. Activated clotting time (ACT) was maintained at 150-170 seconds. Systemic blood pressure goals were a mean arterial pressure of 60-80 mmHg. Both patients successfully recovered the cardiac function and were discharged home without severe complications. ECMO can effectively support pediatric patients after orthotopic heart transplantation to successful recovery despite the use of extreme donor/recipient size mismatch.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials