ArticleScientific reports2016
Multimodal Imaging and Lighting Bias Correction for Improved μPAD-based Water Quality Monitoring via Smartphones.
Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Soil microbiome characterization and its future directions with biosensing.Journal of biological engineering · 2024Article
- A smartphone-based approach for comprehensive soil microbiome profiling.Applied physics reviews · 2024Article
- Article
- Machine learning classification of bacterial species using mix-and-match reagents on paper microfluidic chips and smartphone-based capillary flow analysis.Analytical and bioanalytical chemistry · 2022Article
- Human sensor-inspired supervised machine learning of smartphone-based paper microfluidic analysis for bacterial species classification.Biosensors & bioelectronics · 2021Article
- Development of miniaturized fluorimetric device for caffeine determination using a smartphone.RSC advances · 2019Article
- Cell phone based colorimetric analysis for point-of-care settings.The Analyst · 2019Article
- Point-of-care Colorimetric Analysis through Smartphone Video.Sensors and actuators. B, Chemical · 2019Article
- Article
- Sub-nanoliter, real-time flow monitoring in microfluidic chips using a portable device and smartphone.Scientific reports · 2018Article
- Challenges in paper-based fluorogenic optical sensing with smartphones.Nano convergence · 2018Review
- Portable detection of trace metals in airborne particulates and sedimentsBiomicrofluidics · 2017Article
- Depletion of Cr(VI) from aqueous solution by heat dried biomass of a newly isolated fungus Arthrinium malaysianum: A mechanistic approach.Scientific reports · 2017Article
- Evaluation of the SeedCounter, A Mobile Application for Grain Phenotyping.Frontiers in plant science · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Smartphone image-based sensing of microfluidic paper analytical devices (μPADs) offers low-cost and mobile evaluation of water quality. However, consistent quantification is a challenge due to variable environmental, paper, and lighting conditions, especially across large multi-target μPADs. Compensations must be made for variations between images to achieve reproducible results without a separate lighting enclosure. We thus developed a simple method using triple-reference point normalization and a fast-Fourier transform (FFT)-based pre-processing scheme to quantify consistent reflected light intensity signals under variable lighting and channel conditions. This technique was evaluated using various light sources, lighting angles, imaging backgrounds, and imaging heights. Further testing evaluated its handle of absorbance, quenching, and relative scattering intensity measurements from assays detecting four water contaminants - Cr(VI), total chlorine, caffeine, and E. coli K12 - at similar wavelengths using the green channel of RGB images. Between assays, this algorithm reduced error from μPAD surface inconsistencies and cross-image lighting gradients. Although the algorithm could not completely remove the anomalies arising from point shadows within channels or some non-uniform background reflections, it still afforded order-of-magnitude quantification and stable assay specificity under these conditions, offering one route toward improving smartphone quantification of μPAD assays for in-field water quality monitoring.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.