Evidence map›Paper›PMID 27283009›Full record

ArticleJournal of intensive care medicine2018

Correlation of Venous Blood Gas and Pulse Oximetry With Arterial Blood Gas in the Undifferentiated Critically Ill Patient.

Eli Zeserson, Ben Goodgame, J Daniel Hess, Kristine Schultz, Cynthia Hoon, Keith Lamb, Vinay Maheshwari, Steven Johnson, Mia Papas, James Reed and 1 more

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in Journal of intensive care medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04409470 (Venous Versus Arterial Blood Gas Sampling in Undifferentiated Emergency Patients), which is not on this map. Cited by 41 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed, 1 pooled it
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04409470 completednot on this mapstarted 2021, after this paper: background citation

Venous Versus Arterial Blood Gas Sampling in Undifferentiated Emergency Patients

TypeobservationalSponsorUniversity Hospital, LinkoepingRan2021 to 2022Enrolled250ConditionsDyspnea, HypercapniaArmsBlood gas sampling from artery and vein
3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 1 synthesis or guideline pooled it, 92 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Observational
  7. Article
  8. Article
  9. A Wearable Prototype Measuring PtcCOIEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference · 2024
    Article
  10. Article
  11. Article
  12. Observational
  13. Agreement of pCOIntensive care medicine experimental · 2023
    Article
  14. Review
  15. Article
  16. Observational
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 1 country.

Eli Zeserson1 Department of Emergency Medicine, Christiana Care Health System, Newark, DE, USA.
Ben Goodgame1 Department of Emergency Medicine, Christiana Care Health System, Newark, DE, USA.
J Daniel Hess1 Department of Emergency Medicine, Christiana Care Health System, Newark, DE, USA.
Kristine Schultz1 Department of Emergency Medicine, Christiana Care Health System, Newark, DE, USA.
Cynthia Hoon1 Department of Emergency Medicine, Christiana Care Health System, Newark, DE, USA.
Keith Lamb2 Department of Respiratory Care, Unity Point Health, Des Moines, IA, USA.
Vinay Maheshwari3 Department of Medicine, Christiana Care Health System, Newark, DE, USA.
Steven Johnson4 Department of Surgery, Capital Health, Trenton, NJ, USA.
Mia Papas5 Department of Behavioral Health and Nutrition, University of Delaware, Newark, DE, USA.
James Reed1 Department of Emergency Medicine, Christiana Care Health System, Newark, DE, USA.
Michael Breyer6 Department of Emergency Medicine, Denver Health Medical Center, Denver, CO, USA.
Christiana Care Health System · USCapital Health · USUnityPoint Health · USUniversity of Colorado Denver · USUniversity of Delaware · US

Funding

Subproject Title: Clinical Research Education, Mentoring and Career Development CoreU54GM104941 · NIGMS · UNIVERSITY OF DELAWARE · PI Susan Poland Giancola · 2013 to 2026
$60.5M
NIGMS NIH HHS U54 GM104941
6 · The paper itself

Abstract

rationaleBlood gas analysis is often used to assess acid-base, ventilation, and oxygenation status in critically ill patients. Although arterial blood gas (ABG) analysis remains the gold standard, venous blood gas (VBG) analysis has been shown to correlate with ABG analysis and has been proposed as a safer less invasive alternative to ABG analysis.

objectiveThe purpose of this study was to evaluate the correlation of VBG analysis plus pulse oximetry (SpO

methodsWe performed a prospective cohort study of patients in the emergency department (ED) and intensive care unit (ICU) at a single academic tertiary referral center. Patients were eligible for enrollment if the treating physician ordered an ABG. Statistical analysis of VBG, SpO MAIN

resultsThere were 156 patients enrolled, and 129 patients completed the study. Of the patients completing the study, 53 (41.1%) were in the ED, 41 (31.8%) were in the medical ICU, and 35 (27.1%) were in the surgical ICU. The mean difference for pH between VBG and ABG was 0.03 (95% confidence interval: 0.03-0.04) with a Pearson correlation of 0.94. The mean difference for pCO

conclusionIn this population of undifferentiated critically ill patients, pH and pCO

Indexed as

Critical IllnessAdultAgedAged, 80 and overBlood Gas AnalysisCritical CareFemaleHumansMaleMiddle AgedOximetryOxygenProspective StudiesYoung AdultOxygenblood gas analysiscritical careoximetry

Identifiers

PMID27283009
PMCPMC5885755
OpenAlexW2414673008

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.