Evidence map›Paper›PMID 27251196›Full record

ArticleInhalation toxicology2016

Comparison of cell counting methods in rodent pulmonary toxicity studies: automated and manual protocols and considerations for experimental design.

Patti C Zeidler-Erdely, James M Antonini, Terence G Meighan, Shih-Houng Young, Tracy J Eye, Mary Ann Hammer, Aaron Erdely

Open access · greenAbstract read
In one paragraph

Article in Inhalation toxicology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Patti C Zeidler-Erdelya Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Morgantown , WV , USA and.
James M Antoninia Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Morgantown , WV , USA and.
Terence G Meighana Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Morgantown , WV , USA and.
Shih-Houng Youngb Army Public Health Center (Provisional) , Aberdeen Proving Ground , MD , USA.
Tracy J Eyea Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Morgantown , WV , USA and.
Mary Ann Hammera Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Morgantown , WV , USA and.
Aaron Erdelya Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Morgantown , WV , USA and.
National Institute for Occupational Safety and Health · USU.S. Army Center for Health Promotion and Preventive Medicine · US

Funding

Intramural CDC HHS CC999999
6 · The paper itself

Abstract

Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.

Indexed as

Air PollutantsAnimalsBronchoalveolar Lavage FluidCell CountFlow CytometryInhalation ExposureLinear ModelsLungMaleMetalsMiceMice, Inbred C57BLParticulate MatterRatsRats, Sprague-DawleyResearch DesignAir PollutantsMetalsParticulate MatterBronchoalveolar lavagecarbon nanotubescytotoxicityflow cytometryhemocytometermetalswelding fume

Identifiers

PMID27251196
PMCPMC4911306
OpenAlexW2415356838

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked