ReviewActa orthopaedica2016
Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty.
Review in Acta orthopaedica, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
34 citing papers in PubMed, 7 syntheses or guidelines pooled it.
- Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis.Archives of orthopaedic and trauma surgery · 2023Pooled it
- Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Pooled it
- Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-specific Instruments or Standard Cutting Guides in TKA? A Network Meta-analysis.Clinical orthopaedics and related research · 2020Pooled it
- Patient-Specific or Conventional Instrumentations: A Meta-analysis of Randomized Controlled Trials.BioMed research international · 2020Pooled it
- Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019Pooled it
- The original Akagi line is the most reliable: a systematic review of landmarks for rotational alignment of the tibial component in TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019Pooled it
- Pooled it
- Effects of patient-specific positioning guides (PSPGs) vs. conventional instrumentation on patient-reported outcome in total knee arthroplasty: secondary analysis of a randomized controlled trial after 5 years.Acta orthopaedica · 2023Trial
- The Bony Resection Accuracy with Patient-Specific Instruments during Total Knee Arthroplasty: A Retrospective Case Series Study.BioMed research international · 2021Trial
- Patient-specific Instrumentation Affects Rotational Alignment of the Femoral Component in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.Orthopaedic surgery · 2019Trial
- Imageless robotic assistance versus laser-projected mechanical-axis guidance in total knee arthroplasty: a deformity-stratified comparative cohort study.Journal of robotic surgery · 2026Article
- The influence of implant factors on patient outcomes in primary total knee arthroplasty.Journal of orthopaedics · 2024Article
- Comparison of the accuracy and efficacy of different assistive techniques in primary total knee arthroplasty: A network meta-analysis.Journal of experimental orthopaedics · 2024Article
- Article
- The Role of 3D-Printed Patient-Specific Instrumentation in Total Knee Arthroplasty: A Literature Review.Cureus · 2023Review
- Influence of Mechanical Alignment on Functional Knee Phenotypes and Clinical Outcomes in Primary TKA: A 1-Year Prospective Analysis.Journal of personalized medicine · 2023Article
- Surgery Training and Simulation Using Virtual and Augmented Reality for Knee Arthroplasty.Cureus · 2022Review
- Surgeon Dominated Design Can Improve the Accuracy of Patient-Specific Instruments in Kinematically Aligned TKA.Journal of personalized medicine · 2022Article
- Comparative Cost Analysis of Four Different Computer-Assisted Technologies to Implant a Total Knee Arthroplasty over Conventional Instrumentation.Journal of personalized medicine · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose - Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. Patients and methods - We identified randomized and quasi-randomized controlled trials (RCTs) comparing patient-specific and conventional instrumentation in TKA. Weighted mean differences and risk ratios were determined for radiographic accuracy, operation time, hospital stay, blood loss, number of surgical trays required, and patient-reported outcome measures. Results - 21 RCTs involving 1,587 TKAs were included. Patient-specific instrumentation resulted in slightly more accurate hip-knee-ankle axis (0.3°), coronal femoral alignment (0.3°, femoral flexion (0.9°), tibial slope (0.7°), and femoral component rotation (0.5°). The risk ratio of a coronal plane outlier (> 3° deviation of chosen target) for the tibial component was statistically significantly increased in the PSI group (RR =1.64). No significance was found for other radiographic measures. Operation time, blood loss, and transfusion rate were similar. Hospital stay was significantly shortened, by approximately 8 h, and the number of surgical trays used decreased by 4 in the PSI group. Knee Society scores and Oxford knee scores were similar. Interpretation - Patient-specific instrumentation does not result in clinically meaningful improvement in alignment, fewer outliers, or better early patient-reported outcome measures. Efficiency is improved by reducing the number of trays used, but PSI does not reduce operation time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.