Evidence map›Paper›PMID 27245139›Full record

ArticleThe British journal of radiology2016

Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta.

Alice Wielandner, Dietrich Beitzke, Ruediger Schernthaner, Florian Wolf, Christina Langenberger, Alfred Stadler, Christian Loewe

Open access · greenAbstract read
In one paragraph

Article in The British journal of radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Medical Radiology: Current Progress.Diagnostics (Basel, Switzerland) · 2023
    Review
  3. Review
  4. Article
  5. Computed tomography in paediatric heart disease.The British journal of radiology · 2018
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Alice Wielandner1 Department of Radiology, Medical University of Vienna, Vienna, Austria.
Dietrich Beitzke1 Department of Radiology, Medical University of Vienna, Vienna, Austria.
Ruediger Schernthaner1 Department of Radiology, Medical University of Vienna, Vienna, Austria.
Florian Wolf1 Department of Radiology, Medical University of Vienna, Vienna, Austria.
Christina Langenberger1 Department of Radiology, Medical University of Vienna, Vienna, Austria.
Alfred Stadler2 Department of Radiology, Krankenhaus Hietzing, Vienna, Austria.
Christian Loewe1 Department of Radiology, Medical University of Vienna, Vienna, Austria.
Medical University of Vienna · ATKlinik Hietzing · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objective: To compare electrocardiographic (ECG)-triggered high-pitch (HP) dual-source CT angiography (CTA) with non-ECG-triggered HP CTA of the aorta, particularly the ascending aorta, with regard to image quality, motion artefacts, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and radiation dose.

methods: 59 consecutive patients who had been referred for CTA for known or suspected aortic disease, previous aortic intervention or planned transapical or transfemoral aortic valve implantation were prospectively included. Patients underwent CTAs with HP, using a dual-source CTA system, with [control group (Group A); n = 30] or without (Group B; n = 29) ECG triggering after randomization. For evaluation, image quality and a motion artefact score (MAS) were assessed in a blinded fashion at different predefined anatomic regions. CNR and SNR were measured at the same levels. Radiation dose estimates and contrast enhancement were compared between the two groups.

results: There were no significant differences for image quality and MAS. The intra-arterial contrast resolution was significantly higher at the level of the aortic arch and descending aorta in the non-triggered group (CNR values, p = 0.002-0.018). No significant differences in the radiation dose were found.

conclusion: Non-triggered HP dual-source CTA provided comparable results with regard to image quality, MAS, CNR, SNR and radiation doses compared with ECG-triggered HP CTA. Therefore, ECG triggering of the ascending aorta might be obviated when HP scanning is available. ADVANCES IN KNOWLEDGE:: HP dual-source CTA might obviate ECG triggering in the ascending aorta. Non-triggered HP CTA of the ascending aorta provides an excellent image quality.

Identifiers

PMID27245139
PMCPMC5124891
OpenAlexW2416329842

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked