Evidence map›Paper›PMID 27243628›Full record

ArticlePloS one2016

Effect of Surface Modifications of Ti40Zr10Cu38Pd12 Bulk Metallic Glass and Ti-6Al-4V Alloy on Human Osteoblasts In Vitro Biocompatibility.

Andreu Blanquer, Anna Hynowska, Carme Nogués, Elena Ibáñez, Jordi Sort, Maria Dolors Baró, Berna Özkale, Salvador Pané, Eva Pellicer, Leonardo Barrios

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Andreu BlanquerDepartament de Biologia Cel·lular, Fisiologia i Immunologia, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Anna HynowskaDepartament de Física, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Carme NoguésDepartament de Biologia Cel·lular, Fisiologia i Immunologia, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Elena IbáñezDepartament de Biologia Cel·lular, Fisiologia i Immunologia, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Jordi SortDepartament de Física, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Maria Dolors BaróDepartament de Física, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Berna ÖzkaleMulti-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Zurich, Switzerland.
Salvador PanéMulti-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Zurich, Switzerland.
Eva PellicerDepartament de Física, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.
Leonardo BarriosDepartament de Biologia Cel·lular, Fisiologia i Immunologia, Universitat Autònoma de Barcelona, Edifici Cc, Bellaterra, Spain.ORCID http://orcid.org/0000-0002-6151-8503
Universitat Autònoma de Barcelona · ESETH Zurich · CHInstitució Catalana de Recerca i Estudis Avançats · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of biocompatible materials, including bulk metallic glasses (BMGs), for tissue regeneration and transplantation is increasing. The good mechanical and corrosion properties of Ti40Zr10Cu38Pd12 BMG and its previously described biocompatibility makes it a potential candidate for medical applications. However, it is known that surface properties like topography might play an important role in regulating cell adhesion, proliferation and differentiation. Thus, in the present study, Ti40Zr10Cu38Pd12 BMG and Ti6-Al-4V alloy were surface-modified electrochemically (nanomesh) or physically (microscratched) to investigate the effect of material topography on human osteoblasts cells (Saos-2) adhesion, proliferation and differentiation. For comparative purposes, the effect of mirror-like polished surfaces was also studied. Electrochemical treatments led to a highly interconnected hierarchical porous structure rich in oxides, which have been described to improve corrosion resistance, whereas microscratched surfaces showed a groove pattern with parallel trenches. Cell viability was higher than 96% for the three topographies tested and for both alloy compositions. In all cases, cells were able to adhere, proliferate and differentiate on the alloys, hence indicating that surface topography plays a minor role on these processes, although a clear cell orientation was observed on microscratched surfaces. Overall, our results provide further evidence that Ti40Zr10Cu38Pd12 BMG is an excellent candidate, in the present two topographies, for bone repair purposes.

Indexed as

AlloysBiocompatible MaterialsBone-Implant InterfaceBone RegenerationCell AdhesionCell DifferentiationCell Line, TumorCell ProliferationCell SurvivalElectrochemical TechniquesGlassHumansOsseointegrationOsteoblastsOsteogenesisProstheses and ImplantsAlloysBiocompatible MaterialsTitaniumtitanium alloy (TiAl6V4)

Identifiers

PMID27243628
PMCPMC4887090
OpenAlexW2412849976

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.