Evidence map›Paper›PMID 27227361›Full record

ArticleACS nano2016

Scalable Production of Molybdenum Disulfide Based Biosensors.

Carl H Naylor, Nicholas J Kybert, Camilla Schneier, Jin Xi, Gabriela Romero, Jeffery G Saven, Renyu Liu, A T Charlie Johnson

Open access · greenAbstract read
In one paragraph

Article in ACS nano, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
6.8field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 81 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Bio-Separated and Gate-Free 2D MoSNanomaterials (Basel, Switzerland) · 2021
    Article
  5. Article
  6. Review
  7. MoS2d materials · 2020
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Carl H NaylorDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
Nicholas J KybertDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
Camilla SchneierDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
Jin XiDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
Gabriela RomeroDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
Jeffery G SavenDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
Renyu LiuDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
A T Charlie JohnsonDepartment of Physics and Astronomy, ‡Department of Anesthesiology and Critical Care, and §Department of Chemistry, University of Pennsylvania , Philadelphia 19104, United States.
University of Pennsylvania · US

Funding

Water soluble variants of the human mu opioid receptorR01GM111421 · NIGMS · UNIVERSITY OF PENNSYLVANIA · PI LIU, RENYU · 2014 to 2018
$1.7M
Structural Approaches for Understanding Opioid and ??-Receptor InteractionsK08GM093115 · NIGMS · UNIVERSITY OF PENNSYLVANIA · PI LIU, RENYU · 2010 to 2013
$505k
NIGMS NIH HHS K08 GM093115NIGMS NIH HHS R01 GM111421
6 · The paper itself

Abstract

We demonstrate arrays of opioid biosensors based on chemical vapor deposition grown molybdenum disulfide (MoS2) field effect transistors (FETs) coupled to a computationally redesigned, water-soluble variant of the μ-opioid receptor (MOR). By transferring dense films of monolayer MoS2 crystals onto prefabricated electrode arrays, we obtain high-quality FETs with clean surfaces that allow for reproducible protein attachment. The fabrication yield of MoS2 FETs and biosensors exceeds 95%, with an average mobility of 2.0 cm(2) V(-1) s(-1) (36 cm(2) V(-1) s(-1)) at room temperature under ambient (in vacuo). An atomic length nickel-mediated linker chemistry enables target binding events that occur very close to the MoS2 surface to maximize sensitivity. The biosensor response calibration curve for a synthetic opioid peptide known to bind to the wild-type MOR indicates binding affinity that matches values determined using traditional techniques and a limit of detection ∼3 nM (1.5 ng/mL). The combination of scalable array fabrication and rapid, precise binding readout enabled by the MoS2 transistor offers the prospect of a solid-state drug testing platform for rapid readout of the interactions between novel drugs and their intended protein targets.

Indexed as

Biosensing TechniquesDisulfidesMolybdenumAnalgesics, OpioidReceptors, Opioid, muWaterAnalgesics, OpioidDisulfidesMolybdenummolybdenum disulfideReceptors, Opioid, muWaterbiosensorsmonolayer MoS2opioidsscalabletransition-metal dichalcogenide

Identifiers

PMID27227361
PMCPMC4949953
OpenAlexW2395705820

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.