Evidence map›Paper›PMID 27222246›Full record

ArticleUltrasound in medicine & biology2016

Design and Testing of a Single-Element Ultrasound Viscoelastography System for Point-of-Care Edema Quantification.

John J Pitre, Leo B Koziol, Grant H Kruger, Alan Vollmer, Jonathan Ophir, Jean-Jacques Ammann, William F Weitzel, Joseph L Bull

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

John J PitreDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Leo B KoziolDepartment of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA; Department of Veterans Affairs Medical Center, Ann Arbor, Michigan, USA.
Grant H KrugerDepartment of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Department of Anesthesiology, University of Michigan, Ann Arbor, Michigan, USA.
Alan VollmerDepartment of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA; Department of Veterans Affairs Medical Center, Ann Arbor, Michigan, USA.
Jonathan OphirUltrasonics Laboratory, Department of Diagnostic and Interventional Imaging, University of Texas Medical School, Houston, Texas, USA.
Jean-Jacques AmmannDepartment of Physics, Universidad de Santiago, Santiago, Chile; G.E.A. Universitas SpA, Santiago, Chile.
William F WeitzelDepartment of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA; Department of Veterans Affairs Medical Center, Ann Arbor, Michigan, USA.
Joseph L BullDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA. Electronic address: joebull@umich.edu.
University of Michigan–Ann Arbor · USUniversidad de Santiago de Chile · CL

Funding

Telehealth-Enabled Ultrasound-Bioimpedance Viscoelastographic Edema MonitoringI01BX001684 · VA · VETERANS HEALTH ADMINISTRATION · PI WEITZEL, WILLIAM F · 2012 to 2015
–
BLRD VA I01 BX001684
6 · The paper itself

Abstract

Management of fluid overload in patients with end-stage renal disease represents a unique challenge to clinical practice because of the lack of accurate and objective measurement methods. Currently, peripheral edema is subjectively assessed by palpation of the patient's extremities, ostensibly a qualitative indication of tissue viscoelastic properties. New robust quantitative estimates of tissue fluid content would allow clinicians to better guide treatment, minimizing reactive treatment decision making. Ultrasound viscoelastography (UVE) can be used to estimate strain in viscoelastic tissue, deriving material properties that can help guide treatment. We are developing and testing a simple, low-cost UVE system using a single-element imaging transducer that is simpler and less computationally demanding than array-based systems. This benchtop validation study tested the feasibility of using the UVE system by measuring the mechanical properties of a tissue-mimicking material under large strains. We generated depth-dependent creep curves and viscoelastic parameter maps of time constants and elastic moduli for the Kelvin model of viscoelasticity. During testing, the UVE system performed well, with mean UVE-measured strain matching standard mechanical testing with maximum absolute errors ≤4%. Motion tracking revealed high correlation and signal-to-noise ratios, indicating that the system is reliable.

Indexed as

Point-of-Care SystemsEdemaElasticity Imaging TechniquesElastic ModulusEquipment DesignPhantoms, ImagingReproducibility of ResultsViscosityCreep experimentEdemaEnd-stage renal diseasePoint-of-carePoroelasticitySpeckle trackingSrain imagingUltrasoundViscoelastography

Identifiers

PMID27222246
PMCPMC4983502
OpenAlexW2398850595

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked