Evidence map›Paper›PMID 27219618›Full record

ArticlePloS one2016

The New 3D Printed Left Atrial Appendage Closure with a Novel Holdfast Device: A Pre-Clinical Feasibility Animal Study.

M Brzeziński, K Bury, L Dąbrowski, P Holak, A Sejda, M Pawlak, D Jagielak, Z Adamiak, J Rogowski

Abstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

M BrzezińskiDepartment of Cardiac and Vascular Surgery, Medical University of Gdansk, Gdansk, Poland.
K BuryDepartment of Cardiac and Vascular Surgery, Medical University of Gdansk, Gdansk, Poland.
L DąbrowskiFaculty of Mechanical Engineering, Gdansk University of Technology, Gdansk, Poland.
P HolakDepartment of Surgery and Roentgenology, Faculty of Veterinary Medicine, University of Warmia and Mazury Olsztyn, Olsztyn, Poland.
A SejdaDepartment of Pathomorphology, Medical University of Gdansk, Gdansk, Poland.
M PawlakDepartment of Cardiac and Vascular Surgery, Medical University of Gdansk, Gdansk, Poland.
D JagielakDepartment of Cardiac and Vascular Surgery, Medical University of Gdansk, Gdansk, Poland.
Z AdamiakDepartment of Surgery and Roentgenology, Faculty of Veterinary Medicine, University of Warmia and Mazury Olsztyn, Olsztyn, Poland.
J RogowskiDepartment of Cardiac and Vascular Surgery, Medical University of Gdansk, Gdansk, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMany patients undergoing cardiac surgery have risk factors for both atrial fibrillation (AF) and stroke. The left atrial appendage (LAA) is the primary site for thrombi formation. The most severe complication of emboli derived from LAA is stroke, which is associated with a 12-month mortality rate of 38% and a 12-month recurrence rate of 17%. The most common form of treatment for atrial fibrillation and stroke prevention is the pharmacological therapy with anticoagulants. Nonetheless this form of therapy is associated with high risk of major bleeding. Therefore LAA occlusion devices should be tested for their ability to reduce future cerebral ischemic events in patients with high-risk of haemorrhage.

aimThe aim of this study was to evaluate the safety and feasibility of a novel left atrial appendage exclusion device with a minimally invasive introducer in a swine model. MATERIALS AND

methodsA completely novel LAA device, which is composed of two tubes connected together using a specially created bail, was designed using finite element modelling (FEM) to obtain an optimal support force of 36 N at the closure line. The monolithic form of the occluder was obtained by using additive manufacturing of granular PA2200 powder with the technology of selective laser sintering (SLS). Fifteen swine were included in the feasibility tests, with 10 animals undergoing fourteen days of follow-up and 5 animals undergoing long-term observation of 3 months. For one animal, the follow-up was further prolonged to 6 months. The device was placed via minithoracotomy. After the observation period, all of the animals were euthanized, and their hearts were tested for LAA closure and local inflammatory and tissue response.

resultsAfter the defined observation period, all fifteen hearts were explanted. In all cases the full closure of the LAA was achieved. The macroscopic and microscopic evaluation of the explanted hearts showed that all devices were securely integrated in the surrounding tissues. No pericarditis or macroscopic signs of inflammation at the site of the device were found. All pigs were in good condition with normal weight gain and no other clinical symptoms.

conclusionThis novel 3D printed left atrial appendage closure technique with a novel holdfast device was proven to be safe and feasible in all pigs. A benign healing process without inflammation and damage to the surrounding structures or evidence of new thrombi formation was observed. Moreover, the uncomplicated survival and full LAA exclusion in all animals demonstrate the efficacy of this novel and relatively cheap device. Further clinical evaluation and implementation studies should be performed to introduce this new technology into clinical practice.

Indexed as

AnimalsAtrial AppendageCardiac Surgical ProceduresDisease Models, AnimalFemaleMalePrinting, Three-DimensionalSurvival AnalysisSwineThoracotomyTreatment OutcomeWound Healing

Identifiers

PMID27219618
PMCPMC4878741

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.