Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.

Chenchen Bing, Robert M Staruch, Matti Tillander, Max O Köhler, Charles Mougenot, Mika Ylihautala, Theodore W Laetsch, Rajiv Chopra

Open access · bronzeAbstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 55 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Review
  5. Article
  6. Technical advances in motion-robust MR thermometry.Magnetic resonance in medicine · 2024
    Review
  7. Article
  8. Article
  9. Volumetric hyperthermia delivery using the ExAblate Body MR-guided focused ultrasound system.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2024
    Article
  10. Article
  11. Article
  12. Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023
    Article
  13. Article
  14. Article
  15. Review
  16. The effect of injected dose on localized tumor accumulation and cardiac uptake of doxorubicin in a Vx2 rabbit tumor model using MR-HIFU mild hyperthermia and thermosensitive liposomes.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2020
    Article
  17. Article
  18. Article
  19. Article
  20. Feasibility and safety assessment of magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU)-mediated mild hyperthermia in pelvic targets evaluated using anInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Chenchen Binga Department of Radiology , University of Texas Southwestern Medical Center , Dallas , Texas , USA ;
Robert M Starucha Department of Radiology , University of Texas Southwestern Medical Center , Dallas , Texas , USA ;
Matti Tillandere Philips Healthcare , Vantaa , Finland ;
Max O Köhlere Philips Healthcare , Vantaa , Finland ;
Charles Mougenotd Philips Healthcare , Toronto , ON , Canada ;
Mika Ylihautalae Philips Healthcare , Vantaa , Finland ;
Theodore W Laetschf Department of Pediatrics , University of Texas Southwestern Medical Center , Dallas , Texas , USA ;
Rajiv Chopraa Department of Radiology , University of Texas Southwestern Medical Center , Dallas , Texas , USA ;
The University of Texas Southwestern Medical Center · USPhilips (Finland) · FIPhilips (Canada) · CA

Funding

Image-guided doxorubicin delivery for pediatric sarcomasR01CA199937 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI CHOPRA, RAJIV, LAETSCH, THEODORE WILLIS · 2015 to 2019
$2.8M
NCI NIH HHS R01 CA199937
6 · The paper itself

Abstract

unlabelledThere is growing interest in performing hyperthermia treatments with clinical magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) therapy systems designed for tissue ablation. During hyperthermia treatment, however, due to the narrow therapeutic window (41-45 °C), careful evaluation of the accuracy of proton resonant frequency (PRF) shift MR thermometry for these types of exposures is required. PURPOSE: The purpose of this study was to evaluate the accuracy of MR thermometry using a clinical MR-HIFU system equipped with a hyperthermia treatment algorithm.

methodsMild heating was performed in a tissue-mimicking phantom with implanted temperature sensors using the clinical MR-HIFU system. The influence of image-acquisition settings and post-acquisition correction algorithms on the accuracy of temperature measurements was investigated. The ability to achieve uniform heating for up to 40 min was evaluated in rabbit experiments.

resultsAutomatic centre-frequency adjustments prior to image-acquisition corrected the image-shifts in the order of 0.1 mm/min. Zero- and first-order phase variations were observed over time, supporting the use of a combined drift correction algorithm. The temperature accuracy achieved using both centre-frequency adjustment and the combined drift correction algorithm was 0.57° ± 0.58 °C in the heated region and 0.54° ± 0.42 °C in the unheated region.

conclusionAccurate temperature monitoring of hyperthermia exposures using PRF shift MR thermometry is possible through careful implementation of image-acquisition settings and drift correction algorithms. For the evaluated clinical MR-HIFU system, centre-frequency adjustment eliminated image shifts, and a combined drift correction algorithm achieved temperature measurements with an acceptable accuracy for monitoring and controlling hyperthermia exposures.

Indexed as

High-Intensity Focused Ultrasound AblationHyperthermia, InducedAnimalsFemaleMagnetic Resonance ImagingNeoplasmsRabbitsThermometryMild hyperthermiaMR-HIFUphase driftPRF-shift MR thermometry

Identifiers

PMID27210733
PMCPMC5045807
OpenAlexW2400912737

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.