ArticlePulse (Basel, Switzerland)2016

Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Willem J Verberk, Hao-Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, Chen-Huan Chen

Abstract read
In one paragraph

Article in Pulse (Basel, Switzerland), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Willem J VerberkCardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands; Department of Research and Development, Microlife Corporation, Taipei, Taiwan, ROC.
Hao-Min ChengDepartment of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan, ROC; Department of Medicine, National Yang-Ming University, Taipei, Taiwan, ROC; Department of Public Health, National Yang-Ming University, Taipei, Taiwan, ROC.
Li-Chih HuangDepartment of Research and Development, Microlife Corporation, Taipei, Taiwan, ROC.
Chia-Ming LinDepartment of Research and Development, Microlife Corporation, Taipei, Taiwan, ROC.
Yao-Pin TengDepartment of Research and Development, Microlife Corporation, Taipei, Taiwan, ROC.
Chen-Huan ChenDepartment of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan, ROC; Department of Medicine, National Yang-Ming University, Taipei, Taiwan, ROC; Department of Public Health, National Yang-Ming University, Taipei, Taiwan, ROC.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accumulating evidence indicates that central blood pressure (CBP) is a better cardiovascular risk predictor than brachial blood pressure (BP). Although more additional benefits of CBP-based treatment above usual hypertension treatment are to be demonstrated, the demand for implementing CBP assessment in general clinical practice is increasing. For this, the measurement procedure must be noninvasive, easy to perform, and cost- and time-efficient. Therefore, oscillometric devices with the possibility to assess CBP seem the best option. Recently, such an oscillometric BP monitor, the Microlife WatchBP Office Central, was developed, which demonstrated its high accuracy in a validation study against invasive BP measurement. Calibration errors of this device are limited because the procedure is automated, standardized, and performed at the same place of and within 30 s from pulse wave assessment. The transformation from the peripheral pulse wave to CBP is done by means of an individual-based pulse wave analysis according to a theory of arterial compliance and wave reflections. In addition, the device has demonstrated to enable a more reliable diagnosis of hypertension by CBP than by peripheral BP, with a lower frequency of over- and underdiagnosis. Altogether, the available clinical evidence suggests that the Microlife WatchBP Office Central fulfills the criteria for general clinical use.

Indexed as

Blood pressureCentral pulse pressureHypertensionOscillometric signalsPressure wave reflectionPulse volume plethysmographyPulse wave analysis