Evidence map›Paper›PMID 27194228›Full record

ArticleJournal of neural transmission (Vienna, Austria : 1996)2016

Experimental new automatic tools for robotic stereotactic neurosurgery: towards "no hands" procedure of leads implantation into a brain target.

P Mazzone, P Arena, L Cantelli, G Spampinato, S Sposato, S Cozzolino, P Demarinis, G Muscato

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of neural transmission (Vienna, Austria : 1996), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

P MazzoneOperative Unit for Stereotactic and Functional Neurosurgery, Regional Center for Functional Neurosurgery and DBS, ASL RM2, Rome, Italy.
P ArenaDIEEI Università degli Studi di Catania, Catania, Italy.
L CantelliDIEEI Università degli Studi di Catania, Catania, Italy.
G SpampinatoMalardalen University, Västerås, Sweden.
S SposatoNeuroradiology, ASL RM2, Rome, Italy.
S CozzolinoAO Cardarelli, Naples, Italy.
P DemarinisAO Cardarelli, Naples, Italy.
G MuscatoDIEEI Università degli Studi di Catania, Catania, Italy. gmuscato@dieei.unict.it.
University of Catania · ITOspedale Antonio Cardarelli · ITAzienda Sanitaria Locale Roma 3 · ITMälardalen University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of robotics in neurosurgery and, particularly, in stereotactic neurosurgery, is becoming more and more adopted because of the great advantages that it offers. Robotic manipulators easily allow to achieve great precision, reliability, and rapidity in the positioning of surgical instruments or devices in the brain. The aim of this work was to experimentally verify a fully automatic "no hands" surgical procedure. The integration of neuroimaging to data for planning the surgery, followed by application of new specific surgical tools, permitted the realization of a fully automated robotic implantation of leads in brain targets. An anthropomorphic commercial manipulator was utilized. In a preliminary phase, a software to plan surgery was developed, and the surgical tools were tested first during a simulation and then on a skull mock-up. In such a way, several tools were developed and tested, and the basis for an innovative surgical procedure arose. The final experimentation was carried out on anesthetized "large white" pigs. The determination of stereotactic parameters for the correct planning to reach the intended target was performed with the same technique currently employed in human stereotactic neurosurgery, and the robotic system revealed to be reliable and precise in reaching the target. The results of this work strengthen the possibility that a neurosurgeon may be substituted by a machine, and may represent the beginning of a new approach in the current clinical practice. Moreover, this possibility may have a great impact not only on stereotactic functional procedures but also on the entire domain of neurosurgery.

Indexed as

RoboticsStereotaxic TechniquesAnimalsBrainBrain DiseasesHumansNeurosurgeryReproducibility of ResultsSwineTherapy, Computer-AssistedBrain stimulationMedical roboticsNeurosurgeryRobot kinematics

Identifiers

PMID27194228
OpenAlexW2402037384

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.