ArticleJournal of magnetic resonance imaging : JMRI2016
Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T.
Article in Journal of magnetic resonance imaging : JMRI, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- A systematic review of repeatability and reproducibility studies of diffusion tensor imaging of cervical spinal cord.The British journal of radiology · 2023Pooled it
- Comparing single-shot EPI and 2D-navigated, multi-shot EPI diffusion tensor imaging acquisitions in the lumbar spinal cord at 3T.Magnetic resonance imaging · 2025Article
- Test-Retest Reliability and Inter-Scanner Reproducibility of Improved Spinal Diffusion Tensor Imaging.Diagnostics (Basel, Switzerland) · 2025Article
- Advanced spinal cord MRI in multiple sclerosis: Current techniques and future directions.NeuroImage. Clinical · 2022Review
- Article
- Diffusion MRI microstructural models in the cervical spinal cord - Application, normative values, and correlations with histological analysis.NeuroImage · 2019Article
- Quantification of DTI in the Pediatric Spinal Cord: Application to Clinical Evaluation in a Healthy Patient Population.AJNR. American journal of neuroradiology · 2019Article
- Reproducibility, temporal stability, and functional correlation of diffusion MR measurements within the spinal cord in patients with asymptomatic cervical stenosis or cervical myelopathy.Journal of neurosurgery. Spine · 2018Observational
- Application and evaluation of NODDI in the cervical spinal cord of multiple sclerosis patients.NeuroImage. Clinical · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
purposeTo empirically characterize and quantify the impact of gradient weighting schemes on the appearance and fidelity of diffusion tensor imaging of the human spinal cord in vivo in clinically relevant scan time equivalents (STE). MATERIALS AND
methodsIn five healthy controls at 3T, we evaluated test-retest reproducibility and performed voxelwise analysis of diffusion tensor imaging (DTI)-derived indices (fractional anisotropy [FA], mean [MD], axial [AD], and radial [RD] diffusivity) in the cervical spinal cord to assess spatial dependencies of measurement error and differences across three different sampling schemes (6, 15, and 32 directions) at STE of 4.5, 9, and 18 minutes. A subjective assessment was also performed.
resultsWith six directions, column-specific errors are highest (effect size = 2.9%, 4.4%, 7.2% for FA in dorsal column, lateral column, and gray matter) and different than the 15-direction scheme (P < 0.05). STE sequences with 15 and 32 directions exhibited small differences in error (P > 0.05). For FA and AD, measurement errors are prevalent in gray matter, while partial volume effects with cerebrospinal fluid heavily influence RD. Measurement errors decreased with increasing scan time (P < 0.01), albeit with diminishing returns at scan times longer than 9 minutes (P < 0.05).
conclusionA 15-direction scheme of 9 minutes yields measurements of the cervical spinal cord with low error. J. Magn. Reson. Imaging 2016;44:1608-1618.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.