Evidence map›Paper›PMID 27189617›Full record

ReviewMolecular neurobiology2017

A Review on Microdialysis Calibration Methods: the Theory and Current Related Efforts.

Chun Min Kho, Siti Kartini Enche Ab Rahim, Zainal Arifin Ahmad, Norazharuddin Shah Abdullah

Abstract readReview
PubMed Publisher
In one paragraph

Review in Molecular neurobiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Antimicrobial agents and chemotherapy · 2025
    Article
  7. Article
  8. Distribution of ganciclovir in the porcine central nervous system.Antimicrobial agents and chemotherapy · 2025
    Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Novel application of in vivo microdialysis in a rat Achilles tendon acute injury model.Journal of applied physiology (Bethesda, Md. : 1985) · 2024
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chun Min KhoStructural Materials Niche Area, School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, 14300, Nibong Tebal, Penang, Malaysia.
Siti Kartini Enche Ab RahimDepartment of Chemical Engineering Technology, Faculty of Engineering Technology, Universiti Malaysia Perlis, Level 1, Block S2, Uniciti Alam Campus, 02100 Sg Chuchuh, Padang Besar, Perlis, Malaysia.
Zainal Arifin AhmadStructural Materials Niche Area, School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, 14300, Nibong Tebal, Penang, Malaysia.
Norazharuddin Shah AbdullahStructural Materials Niche Area, School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, 14300, Nibong Tebal, Penang, Malaysia. azhar.abdullah@usm.my.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microdialysis is a sampling technique first introduced in the late 1950s. Although this technique was originally designed to study endogenous compounds in animal brain, it is later modified to be used in other organs. Additionally, microdialysis is not only able to collect unbound concentration of compounds from tissue sites; this technique can also be used to deliver exogenous compounds to a designated area. Due to its versatility, microdialysis technique is widely employed in a number of areas, including biomedical research. However, for most in vivo studies, the concentration of substance obtained directly from the microdialysis technique does not accurately describe the concentration of the substance on-site. In order to relate the results collected from microdialysis to the actual in vivo condition, a calibration method is required. To date, various microdialysis calibration methods have been reported, with each method being capable to provide valuable insights of the technique itself and its applications. This paper aims to provide a critical review on various calibration methods used in microdialysis applications, inclusive of a detailed description of the microdialysis technique itself to start with. It is expected that this article shall review in detail, the various calibration methods employed, present examples of work related to each calibration method including clinical efforts, plus the advantages and disadvantages of each of the methods.

Indexed as

CalibrationMicrodialysisReference StandardsAbsolute recoveryCalibration methodMicrodialysisRelative recovery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.