Evidence map›Paper›PMID 27189077›Full record

ArticleEuropean journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology2016

The Tego™ needleless connector for hemodialysis catheters may protect against catheter colonization.

M Guembe, M J Pérez-Granda, R Cruces, L Alcalá, E Bouza

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

M GuembeDepartment of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, C/. Dr. Esquerdo, 46, 28007, Madrid, Spain. mariaguembe@hotmail.com.
M J Pérez-GrandaInstituto de Investigación Sanitaria Gregorio Marañón (IISGM), Madrid, Spain.
R CrucesDepartment of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, C/. Dr. Esquerdo, 46, 28007, Madrid, Spain.
L AlcaláDepartment of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, C/. Dr. Esquerdo, 46, 28007, Madrid, Spain.
E BouzaDepartment of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, C/. Dr. Esquerdo, 46, 28007, Madrid, Spain.
Hospital General Universitario Gregorio Marañón · ESCentro de Investigación Biomédica en Red de Enfermedades Respiratorias · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Catheter connectors used in hemodialysis patients are those with open caps to manage high blood flows. However, current guidelines for the prevention of catheter infections recommend closed connectors. Tego™ is a closed connector designed to enable high blood flows. We used an in vitro model to compare the efficacy of Tego™ against contamination with that of standard caps in a real-life practice scenario. The model consisted of 200 blood culture bottles (BCB) with an inserted cannula closed either with Tego™ (100) or with open caps (100). BCB were manipulated using two different methods: under aseptic conditions and with gloves contaminated with a 0.05 McFarland Staphylococcus aureus solution. The BCB were incubated at 37 °C under continuous shaking for up to 7 days or until positive. When a BCB turned positive, 100 μL of the fluid was cultured. The positivity rate and time to positivity of the BCB in each method were compared. Overall, 4.0 % of BCB with Tego™ and 52.0 % of BCB with open caps were positive in the sterile model (p < 0.001), whereas all BCB in the contamination model were positive. We did not find differences regarding the median time (hours) to positivity between Tego™ and the standard cap in the contamination model (19.04 vs. 17.87, p = 0.465). In our model, Tego™ proved to be better than the standard cap for the prevention of contamination when the device was handled under optimal conditions. Moreover, it was as efficient as the standard catheter cap in the contamination model.

Indexed as

Models, BiologicalVascular Access DevicesBlood CultureCatheter-Related InfectionsHumansKaplan-Meier EstimateRenal Dialysis

Identifiers

PMID27189077
OpenAlexW2399516246

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.