Evidence map›Paper›PMID 27188836›Full record

ArticleClinical orthopaedics and related research2016

Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes.

Per-Erik Johanson, Martin Antonsson, Bita Shareghi, Johan Kärrholm

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Hip prosthetic loosening: A very personal review.World journal of orthopedics · 2021
    Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Article
  14. Does particle disease really exist?Acta orthopaedica · 2018
    Article
  15. CORR InsightsClinical orthopaedics and related research · 2017
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Per-Erik JohansonDepartment of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. per-erik.johanson@vgregion.se.
Martin AntonssonDepartment of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Bita ShareghiDepartment of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Johan KärrholmDepartment of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
University of Gothenburg · SESahlgrenska University Hospital · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRadiostereometry (RSA) measurements of early micromotion can predict later failure in hip and knee prostheses. In hip implants, RSA has been particularly helpful in the evaluation of composite-beam stem designs. The Spectron EF Primary stem (Smith & Nephew, London, UK) has shown inferior performance compared with its predecessors in both clinical studies and registry reports. Early RSA studies have shown somewhat greater subsidence for the Spectron EF Primary stem compared with the earlier Spectron EF, but still within boundaries considered to be safe. QUESTIONS/PURPOSES: Our primary research question was whether stem subsidence and rotation for this stem design measured with RSA at 2 years can predict later stem failure. A secondary question was whether high femoral stem offset and small stem sizes, both features specific to the Spectron EF Primary stem compared with its predecessors, are associated with stem failure rate.

methodsTwo hundred forty-seven hips (209 patients with median age 63 years [range, 29-80 years], 65% female, and 77% primary osteoarthritis) with a valid RSA examination at 2 years were selected from four different RSA studies (totaling 279 hips in 236 patients) in our department. The studies were primarily aimed at evaluating cup fixation, bone cement, and polyethylene types. All study patients received a cemented Spectron EF Primary stem. The selected hips had complete followup until stem failure, death, or the end of the followup period. Stem failure was defined as revision of a loose femoral stem or radiological failure with significant osteolysis in Gruen zones 2 to 6. Cox regression analyses were performed to evaluate if stem subsidence and rotation after 2 years, adjusted for age, sex, stem size, standard/high stem offset, and conventional/highly crosslinked polyethylene, could predict later clinical aseptic failure of the stem. We identified 32 stem failures (27 revisions, five radiological failures) at 14 years median followup (range, 3-18 years). Ten-year stem survival was 94% (95% confidence interval [CI], 90%-96%).

resultsStem subsidence at 2 years (adjusted hazard ratio [HR], 6.0; 95% CI, 2.5-15; p < 0.001) and retrotorsion of the stem (adjusted HR, 1.7; 95% CI, 1.1-2.5; p = 0.018) were associated with later stem failure. Further risk factors were male sex (subsidence analysis HR, 6.9; p > 0.001), use of the two smallest stem sizes (HRsize 1, 8.0; p > 0.001, HRsize 2, 1 [reference], HRsize 3+, 0.06; p = 0.035), and the high offset option (HR, 3.1; p = 0.005).

conclusionsStem subsidence and retrotorsion at 2 years can predict later failure in the Spectron EF Primary stem, consistent with earlier findings on composite-beam cemented stems. Small stem size and high-offset stems comprise the main group of underperforming stems. We recommend that premarket small-scale RSA studies be performed after any design change to a THA femoral component, because even seemingly minor design changes may unexpectedly result in inferior performance. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

Hip ProsthesisProsthesis DesignProsthesis FailureAdultAgedAged, 80 and overArthroplasty, Replacement, HipBiomechanical PhenomenaFemaleFemurHip JointHumansKaplan-Meier EstimateMaleMiddle AgedPredictive Value of Tests

Identifiers

PMID27188836
PMCPMC5014811
OpenAlexW2402913753

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.