ArticleMedicine2016
Biomechanical Evaluation of Four Methods for Internal Fixation of Comminuted Subtrochanteric Fractures.
Article in Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05286905 (Biomechanical Testing, Finite Element Analysis and Pilot, Prospective, Randomized, Experimental Clinical Study of Osteosynthesis of Reverse Oblique Peritrochanteric Fractures With PFLP vs Cephalomedullary Nail.), which is not on this map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Biomechanical Testing, Finite Element Analysis and Pilot, Prospective, Randomized, Experimental Clinical Study of Osteosynthesis of Reverse Oblique Peritrochanteric Fractures With PFLP vs Cephalomedullary Nail.
Who cites it
3 citing papers in PubMed, 17 citations in OpenAlex.
- Biomechanical Study of Intramedullary Versus Extramedullary Implants for Four Types of Subtrochanteric Femoral Fracture.Orthopaedic surgery · 2022Article
- An original method of simulating the articular cartilage in the context ofExperimental and therapeutic medicine · 2022Article
- [Finite element study on calcium phosphate ceramic screw implanting after removing dynamic hip screw].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Subtrochanteric fractures are common and result in significant morbidity and mortality. Various kinds of implants have been used to fix it. The aim of this study was to compare the biomechanical performance of PFN, DHS, DCS, and the PFLP in the treatment of subtrochanteric comminuted fractures.A total of 32 antiseptic human femurs from 16 donors were randomly allocated to 4 groups for fixation with PFN, DHS, DCS, and PFLP. A 2-cm cylindrical bone fragment was removed 1 cm below the lesser trochanter to simulate OTA/AO 32-C3.2 post instrumentation fracture. All specimens in single-leg stance situation were preloaded 5 times at 100 N in the axial direction to eliminate the time effect of relaxation and settling, followed by cyclic testing at a rate of 1 Hz with stepwise increasing load. Keeping the valley load at a constant level of 100 N during the entire cyclic test, the peak load, starting at 200 N, was increased by 100 N at 300-cycle steps until a maximum of 1500 cycles or until failure of the bone-implant construct occurred. Each specimen was kept unloaded under 100 N compression for 30 minutes between the 300-cycle steps.Femoral head displacement after 1500 cycles was 1.09 mm ± 0.13 for PFN, 1.78 mm ± 0.25 for DHS, 2.63 mm ± 0.46 for DCS, and 2.26 mm ± 0.16 for PFLP, with significant difference between any 2 implants (P < 0.01). The required load to reach 1-mm femoral head displacement was 563.04 N ± 158.34 for PFN, 485.73 N ± 147.27 for DHS, 258.44 N ± 97.23 for DCS, and 332.68 N ± 100.34 for PFLP. Significant differences were detected between any 2 implants (P < 0.001), except between DCS and PFLP and between DHS and PFN. The number of cycles until 1-mm femoral head displacement was 1458 ± 277 for PFN, 908 ± 184 for DHS, 369 ± 116 for DCS, and 603 ± 162 for PFLP. Significant differences were detected between any 2 implants (P < 0.01), except between DCS and PFLP.From biomechanical point of view, comminuted subtrochanteric fractures OTA/AO 32-C3.2 revealed in the current test setup highest fixation strength with PFN, followed by DHS, PFLP, and DCS.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.