Evidence map›Paper›PMID 27172262›Full record

ArticleRadiation measurements2016

Emergency EPR dosimetry technique using vacuum-stored dry nails.

S Sholom, S W S McKeever

Abstract read
In one paragraph

Article in Radiation measurements, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. The effect of sunlight and UV lamps on EPR signal in nails.Radiation and environmental biophysics · 2019
    Article
  5. Stability of X-band EPR signals from fingernails under vacuum storage.Radiation physics and chemistry (Oxford, England : 1993) · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

S SholomRadiation Dosimetry Group, Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA.
S W S McKeeverRadiation Dosimetry Group, Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA.

Funding

Scientific and Administrative Core: Dartmouth Medical SchoolU19AI091173 · NIAID · DARTMOUTH COLLEGE · PI SWARTS, STEVEN GREGORY · 2010 to 2014
$16.3M
NIAID NIH HHS U19 AI091173
6 · The paper itself

Abstract

Human finger- and toenails have been tested with an X-band EPR technique for different conditions of nail storage. The main radiation-induced signal at g=2.005 demonstrated good stability if the samples were stored in a vacuum at room temperature after nail harvesting and irradiation. On the basis of this phenomenon, a new protocol is proposed to use the nails as possible emergency EPR dosimeters. The dosimetry protocol was tested on laboratory-exposed samples and demonstrated the ability to recover doses in the region 0-10 Gy with an estimated uncertainty of approximately 0.3-0.4 Gy for doses in the range < 2 Gy, increasing to 0.6-0.7 Gy for doses in the range 5-10 Gy.

Identifiers

PMID27172262
PMCPMC4860363

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.