ArticleIEEE journal of translational engineering in health and medicine2014
High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes.
Article in IEEE journal of translational engineering in health and medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 50 citations in OpenAlex.
- Comparative Analysis of Tri-Polar Concentric Ring and Conventional Electrodes for Overt and Covert Speech.Sensors (Basel, Switzerland) · 2026Article
- Comparison of tripolar and traditional EEG recording of the visual evoked potential.Vision research · 2025Article
- Tripolar concentric ring electrodes for capturing localised electroencephalography signals during sleep.Journal of sleep research · 2024Article
- Characteristic analysis of epileptic brain network based on attention mechanism.Scientific reports · 2023Article
- Workshops of the Eighth International Brain-Computer Interface Meeting: BCIs: The Next Frontier.Brain computer interfaces (Abingdon, England) · 2022Article
- Identification of clinically relevant biomarkers of epileptogenesis - a strategic roadmap.Nature reviews. Neurology · 2021Review
- Mobile Electroencephalography for Studying Neural Control of Human Locomotion.Frontiers in human neuroscience · 2021Article
- Power and Coherence in the EEG of the Rat: Impact of Behavioral States, Cortical Area, Lateralization and Light/Dark Phases.Clocks & sleep · 2020Article
- Workshops of the Seventh International Brain-Computer Interface Meeting: Not Getting Lost in Translation.Brain computer interfaces (Abingdon, England) · 2019Article
- Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation.Biomedical engineering online · 2018Article
- Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology.Sensors (Basel, Switzerland) · 2018Article
- Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.Sensors (Basel, Switzerland) · 2016Article
- Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.Measurement : journal of the International Measurement Confederation · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 2 countries.
Funding
Abstract
Epilepsy is the second most prevalent neurological disorder ([Formula: see text]% prevalence) affecting [Formula: see text] million people worldwide with up to 75% from developing countries. The conventional electroencephalogram is plagued with artifacts from movements, muscles, and other sources. Tripolar concentric ring electrodes automatically attenuate muscle artifacts and provide improved signal quality. We performed basic experiments in healthy humans to show that tripolar concentric ring electrodes can indeed record the physiological alpha waves while eyes are closed. We then conducted concurrent recordings with conventional disc electrodes and tripolar concentric ring electrodes from patients with epilepsy. We found that we could detect high frequency oscillations, a marker for early seizure development and epileptogenic zone, on the scalp surface that appeared to become more narrow-band just prior to seizures. High frequency oscillations preceding seizures were present in an average of 35.5% of tripolar concentric ring electrode data channels for all the patients with epilepsy whose seizures were recorded and absent in the corresponding conventional disc electrode data. An average of 78.2% of channels that contained high frequency oscillations were within the seizure onset or irritative zones determined independently by three epileptologists based on conventional disc electrode data and videos.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.