Evidence map›Paper›PMID 27169907›Full record

ArticleLa Radiologia medica2016

320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure.

Ernesto Di Cesare, Antonio Gennarelli, Alessandra Di Sibio, Valentina Felli, Marco Perri, Alessandra Splendiani, Giovanni Luca Gravina, Antonio Barile, Carlo Masciocchi

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Radiofrequency ablation of osteoid osteoma.Acta bio-medica : Atenei Parmensis · 2018
    Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ernesto Di CesareDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy. ernesto.dicesare@cc.univaq.it.
Antonio GennarelliDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Alessandra Di SibioDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Valentina FelliDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Marco PerriDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Alessandra SplendianiDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Giovanni Luca GravinaDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Antonio BarileDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.
Carlo MasciocchiDepartment of Biotechnological and Applied Clinical, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the impact of a 100 kV tube voltage protocol to 120 kV in terms of image quality and radiation dose by a 320 row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC). MATERIALS AND

methodsUsing a propensity matched analysis we compared a group of 135 patients scanned using a 100 kV tube voltage protocol with a group of 135 subjects scanned employing a 120 kV tube voltage setting. In all subjects the heart rate (HR) was <65 bpm and all CT scans were acquired using a prospective ECG gating and AEC strategy. Mean effective radiation dose and subjective and objective (Noise or N, signal to noise ratio or SNR, contrast to noise ratio or CNR) image quality, were evaluated. Subjective quality was assessed by two experienced radiologists using a 5-point scale (0: non diagnostic-4: excellent) using the 15-segment American Heart Association (AHA) coronary artery classification.

resultsMean effective dose and noise were non significantly different between the two groups: mean effective dose was 2.89 ± 0.7 mSv in the 100 kV group and 2.80 ± 0.57 mSv in the 120 kV group (p = 0.25) while noise was 28.9 ± 3.3 in the 120 kV group and 29.05 ± 3.6 in the 100 kV group (p = 0.72). Both SNR and CNR were significantly higher in the 100 kV group than in the 120 kV group. This data agrees with the evidence that subjective quality was significantly higher in the 100 kV group in the middle and distal segmental classes.

conclusionOur study shows that, in using a 320 row CCTA with AEC strategy it is better to employ a 100 kV tube voltage protocol because compared to 120 kV tube voltage setting, it appears to significantly improve both subjective and objective image quality without decreasing the mean effective radiation dose.

Indexed as

Cardiac-Gated Imaging TechniquesComputed Tomography AngiographyContrast MediaCoronary DiseaseFemaleHumansMaleMiddle AgedRadiation DosageRadiographic Image Interpretation, Computer-AssistedSignal-To-Noise RatioTriiodobenzoic AcidsContrast MediaiodixanolTriiodobenzoic Acids320-row coronary computed tomography angiography (CCTA)Image qualityRadiation doseTube voltage

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.