ArticleLa Radiologia medica2016
320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure.
Article in La Radiologia medica, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.The British journal of radiology · 2018Pooled it
- Effects of combining multiple dose reduction techniques on coronary computed tomography angiography.World journal of radiology · 2023Article
- A novel computed tomography angiography technique: guided preoperative localization and design of anterolateral thigh perforator flap.Insights into imaging · 2022Article
- Potential increase in radiation-induced DNA double-strand breaks with higher doses of iodine contrast during coronary CT angiography.Medical physics · 2021Article
- Coronary artery disease (CAD) extension-derived risk stratification for asymptomatic diabetic patients: usefulness of low-dose coronary computed tomography angiography (CCTA) in detecting high-risk profile patients.La Radiologia medica · 2020Article
- The influence of image quality on diagnostic performance of a machine learning-based fractional flow reserve derived from coronary CT angiography.European radiology · 2020Article
- Vascular CT and MRI: a practical guide to imaging protocols.Insights into imaging · 2018Review
- Radiofrequency ablation of osteoid osteoma.Acta bio-medica : Atenei Parmensis · 2018Review
- Low Dose versus Standard Single Heartbeat Acquisition Coronary Computed Tomography Angiography.Journal of clinical imaging science · 2018Article
- Integrated non-invasive approach to atherosclerosis with cardiac CT and carotid ultrasound in patients with suspected coronary artery disease.La Radiologia medica · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo compare the impact of a 100 kV tube voltage protocol to 120 kV in terms of image quality and radiation dose by a 320 row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC). MATERIALS AND
methodsUsing a propensity matched analysis we compared a group of 135 patients scanned using a 100 kV tube voltage protocol with a group of 135 subjects scanned employing a 120 kV tube voltage setting. In all subjects the heart rate (HR) was <65 bpm and all CT scans were acquired using a prospective ECG gating and AEC strategy. Mean effective radiation dose and subjective and objective (Noise or N, signal to noise ratio or SNR, contrast to noise ratio or CNR) image quality, were evaluated. Subjective quality was assessed by two experienced radiologists using a 5-point scale (0: non diagnostic-4: excellent) using the 15-segment American Heart Association (AHA) coronary artery classification.
resultsMean effective dose and noise were non significantly different between the two groups: mean effective dose was 2.89 ± 0.7 mSv in the 100 kV group and 2.80 ± 0.57 mSv in the 120 kV group (p = 0.25) while noise was 28.9 ± 3.3 in the 120 kV group and 29.05 ± 3.6 in the 100 kV group (p = 0.72). Both SNR and CNR were significantly higher in the 100 kV group than in the 120 kV group. This data agrees with the evidence that subjective quality was significantly higher in the 100 kV group in the middle and distal segmental classes.
conclusionOur study shows that, in using a 320 row CCTA with AEC strategy it is better to employ a 100 kV tube voltage protocol because compared to 120 kV tube voltage setting, it appears to significantly improve both subjective and objective image quality without decreasing the mean effective radiation dose.
Indexed as
Identifiers
27169907What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.