Evidence map›Paper›PMID 27162776›Full record

ReviewAnnals of translational medicine2016

Patient specific instrumentation in total knee arthroplasty: a state of the art.

Lorenzo Mattei, Pietro Pellegrino, Michel Calò, Alessandro Bistolfi, Filippo Castoldi

Open access · hybridAbstract readReview
In one paragraph

Review in Annals of translational medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 43 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
43citing papers in PubMed, 3 pooled it
8.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

43 citing papers in PubMed, 3 syntheses or guidelines pooled it, 85 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Lorenzo MatteiCTO Hospital, Città della salute e della Scienza, Turin, Italy.
Pietro PellegrinoCTO Hospital, Città della salute e della Scienza, Turin, Italy.
Michel CalòCTO Hospital, Città della salute e della Scienza, Turin, Italy.
Alessandro BistolfiCTO Hospital, Città della salute e della Scienza, Turin, Italy.
Filippo CastoldiCTO Hospital, Città della salute e della Scienza, Turin, Italy.
CTO Hospital · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patient specific instrumentation (PSI) is a modern technique in total knee arthroplasty (TKA) aiming to facilitate the implant of the prosthesis. The customized cutting blocks of the PSI are generated from pre-operative three-dimensional model, using computed tomography (CT) or magnetic resonance imaging (MRI). A correct surgical plan is mandatory for a good surgical implant. The PSI guide takes into account any slight deformities or osteophytes and applies preoperative planning for bone resection, using the pre-determined implant size, position, and rotation. The apparent benefits of this technology are that neutral postoperative alignment is more reproducible, surgical time is decreased, and the entire procedure results more efficient and cost-effective. The use of PSI is indicated when advanced osteoarthritis, severe pain, and limited function/walking ability are present, such as in a standard instrumentation TKA. In addition to that, PSI finds its indication when intra-medullary guides cannot be used. For example, when there is a post-traumatic femoral deformity. Large debates have taken place about this topic during the last years and, at the moment, there is no consensus in literature regarding the accuracy and reliability of PSI as many studies have shown controversial and inconsistent results. Literature does not suggest PSI techniques as a gold standard in TKA, and therefore it cannot be recommended as a standard technique in standard, not complicated primary TKA. Moreover, literature does not underline any improvement in components alignment, surgical time, blood loss or functional outcomes. Nevertheless, many patients who underwent TKA suffered a previous trauma. In case of deformities, like femoral or tibial fractures healed with a malalignment, preoperative planning may result difficult, and some intra-operative technical difficulties can occur, such as the use of intra-medullar rod. In these selected cases, PSIs may be very useful to avoid errors in alignment and planning.

Indexed as

instrumentationPatientspecifictotal knee arthroplasty (TKA)

Identifiers

PMID27162776
PMCPMC4842392
OpenAlexW2336135924

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.