ArticleBiomaterials2016
Visualization and analysis of biomaterial-centered thrombus formation within a defined crevice under flow.
Article in Biomaterials, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Retrograde aortic endograft side-branch design is associated with delayed cervical branch filling: A fluid mechanics scaling analysis.JVS-vascular science · 2026Article
- Improving the hemocompatibility of a porohyperelastic layered vascular graft using luminal reversal microflows.Journal of the mechanical behavior of biomedical materials · 2024Article
- In Vitro and In Silico Characterization of the Aggregation of Thrombi on Textured Ventricular Cannula.Annals of biomedical engineering · 2024Article
- Influence of Hematocrit Level and Integrin αCellular and molecular bioengineering · 2024Article
- The roles of sub-micron and microscale roughness on shear-driven thrombosis on titanium alloy surfaces.Artificial organs · 2023Article
- Mechanisms for Reduced Fibrin Clot Formation on Liquid-Infused Surfaces.Advanced healthcare materials · 2022Article
- Insights Into the Low Rate of In-Pump Thrombosis With the HeartMate 3: Does the Artificial Pulse Improve Washout?Frontiers in cardiovascular medicine · 2022Article
- Kinetics of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions.Journal of clinical laboratory analysis · 2021Article
- Influence of shear rate and surface chemistry on thrombus formation in micro-crevice.Journal of biomechanics · 2021Article
- Article
- Multi-Constituent Simulation of Thrombus Deposition.Scientific reports · 2017Article
- Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study.Frontiers in bioengineering and biotechnology · 2017Article
- High fidelity computational simulation of thrombus formation in Thoratec HeartMate II continuous flow ventricular assist device.Scientific reports · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The blood flow pathway within a device, together with the biomaterial surfaces and status of the patient's blood, are well-recognized factors in the development of thrombotic deposition and subsequent embolization. Blood flow patterns are of particular concern for devices such as blood pumps (i.e. ventricular assist devices, VADs) where shearing forces can be high, volumes are relatively large, and the flow fields can be complex. However, few studies have examined the effect of geometric irregularities on thrombus formation on clinically relevant opaque materials under flow. The objective of this study was to quantify human platelet deposition onto Ti6Al4V alloys, as well as positive and negative control surfaces, in the region of defined crevices (∼50-150 μm in width) that might be encountered in many VADs or other cardiovascular devices. To achieve this, reconstituted fresh human blood with hemoglobin-depleted red blood cells (to achieve optical clarity while maintaining relevant rheology), long working optics, and a custom designed parallel plate flow chamber were employed. The results showed that the least amount of platelet deposition occurred in the largest crevice size examined, which was counterintuitive. The greatest levels of deposition occurred in the 90 μm and 53 μm crevices at the lower wall shear rate. The results suggest that while crevices may be unavoidable in device manufacturing, the crevice size might be tailored, depending on the flow conditions, to reduce the risk of thromboembolic events. Further, these data might be used to improve the accuracy of predictive models of thrombotic deposition in cardiovascular devices to help optimize the blood flow path and reduce device thrombogenicity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.