Evidence map›Paper›PMID 27153188›Full record

ArticleAnalytical chemistry2016

Low Charge and Reduced Mobility of Membrane Protein Complexes Has Implications for Calibration of Collision Cross Section Measurements.

Timothy M Allison, Michael Landreh, Justin L P Benesch, Carol V Robinson

Abstract read
In one paragraph

Article in Analytical chemistry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Ion mobility-mass spectrometry reveals the role of peripheral myelin protein dimers in peripheral neuropathy.Proceedings of the National Academy of Sciences of the United States of America · 2021
    Article
  3. Article
  4. Article
  5. Native IM-Orbitrap MS: Resolving What Was Hidden.Trends in analytical chemistry : TRAC · 2020
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Allostery revealed within lipid binding events to membrane proteins.Proceedings of the National Academy of Sciences of the United States of America · 2018
    Article
  11. Review
  12. Polymers for Traveling Wave Ion Mobility Spectrometry Calibration.Journal of the American Society for Mass Spectrometry · 2017
    Article
  13. Article
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Timothy M Allison *Department of Chemistry, Physical & Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, United Kingdom.
Michael Landreh *Department of Chemistry, Physical & Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, United Kingdom.
Justin L P BeneschDepartment of Chemistry, Physical & Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, United Kingdom.
Carol V RobinsonDepartment of Chemistry, Physical & Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, United Kingdom.

Funding

European Research Council 268851
6 · The paper itself

Abstract

Ion mobility mass spectrometry of integral membrane proteins provides valuable insights into their architecture and stability. Here we show that, due to their lower charge, the average mobility of native-like membrane protein ions is approximately 30% lower than that of soluble proteins of similar mass. This has implications for drift time measurements, made on traveling wave ion mobility mass spectrometers, which have to be calibrated to extract collision cross sections (Ω). Common calibration strategies employ unfolded or native-like soluble protein standards with masses and mobilities comparable to the protein of interest. We compare Ω values for membrane proteins, derived from standard calibration protocols using soluble proteins, to values measured using an RF-confined drift tube. Our results demonstrate that, while common calibration methods underestimate Ω for native-like or unfolded membrane protein complexes, higher mass soluble calibration standards consistently yield more accurate Ω values. These findings enable us to obtain directly structural information for highly charge-reduced complexes by traveling wave ion mobility mass spectrometry.

Indexed as

CalibrationIonsMass SpectrometryMembrane ProteinsOxidation-ReductionIonsMembrane Proteins

Identifiers

PMID27153188
PMCPMC5287392

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.