Trial reportJournal of medical Internet research2016
A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study.
Trial report in Journal of medical Internet research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation.IEEE transactions on bio-medical engineering · 2024Pooled it
- Wearable, cuffless, and portable devices for blood pressure monitoring (2015-2025): a scoping review of technologies, calibration, clinical validation, and regulatory frameworks.Frontiers in digital health · 2026Article
- Practical Application of a New Cuffless Blood Pressure Measurement Method.Pathophysiology : the official journal of the International Society for Pathophysiology · 2023Article
- Automatic Calibration of a Device for Blood Pressure Waveform Measurement.Sensors (Basel, Switzerland) · 2023Article
- Continuous Vital Signs Monitoring with a Wireless Device on a General Ward: A Survey to Explore Nurses' Experiences in a Post-Implementation Period.International journal of environmental research and public health · 2023Article
- Open-Angle Glaucomatous Optic Neuropathy Is Related to Dips Rather Than Increases in the Mean Arterial Pressure Over 24-H.American journal of hypertension · 2022Article
- Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis.European heart journal. Digital health · 2022Review
- Point-of-care testing technologies for the home in chronic kidney disease: a narrative review.Clinical kidney journal · 2021Article
- Noninvasive Continuous Monitoring of Vital Signs With Wearables: Fit for Medical Use?Journal of diabetes science and technology · 2021Article
- Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device.Scientific reports · 2020Article
- Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.Journal of clinical medicine · 2020Review
- Authors' Reply to: Comment on "Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study".Journal of medical Internet research · 2020Article
- Comment on "Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study".Journal of medical Internet research · 2020Article
- Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study.JMIR mHealth and uHealth · 2019Article
- Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study.Journal of medical Internet research · 2019Article
- Cuff-Less Methods for Blood Pressure Telemonitoring.Frontiers in cardiovascular medicine · 2019Review
- Authors' Reply: Comment on "A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study".Journal of medical Internet research · 2018Article
- Blood Pressure Measurement Validation Off the Cuff? Comment on "A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study".Journal of medical Internet research · 2018Article
- Recent Research and Developing Trends of Wearable Sensors for Detecting Blood Pressure.Sensors (Basel, Switzerland) · 2018Review
- Wearable Devices in Clinical Trials: Hype and Hypothesis.Clinical pharmacology and therapeutics · 2018Review
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP self-measurement.
objectiveThe objective of our study was to evaluate the performance of the first release of the Checkme Health Monitor (Viatom Technology), a cuffless BP monitor, in a real-life setting. Furthermore, we wanted to investigate whether the posture of the volunteer and the position of the device relative to the heart level would influence its outcomes.
methodsStudy volunteers fell into 3 BP ranges: high (>160 mmHg), normal (130-160 mmHg), and low (<130 mmHg). All requirements for test environment, observer qualification, volunteer recruitment, and BP measurements were met according to the European Society of Hypertension International Protocol (ESH-IP) for the validation of BP measurement devices. After calibrating the Checkme device, we measured systolic BP with Checkme and a validated, oscillometric reference BP monitor (RM). Measurements were performed in randomized order both in supine and in sitting position, and with Checkme at and above heart level.
resultsWe recruited 52 volunteers, of whom we excluded 15 (12 due to calibration failure with Checkme, 3 due to a variety of reasons). The remaining 37 volunteers were divided into low (n=14), medium (n=13), and high (n=10) BP ranges. There were 18 men and 19 women, with a mean age of 54.1 (SD 14.5) years, and mean recruitment systolic BP of 141.7 (SD 24.7) mmHg. BP results obtained by RM and Checkme correlated well. In the supine position, the difference between the RM and Checkme was >5 mmHg in 17 of 37 volunteers (46%), of whom 9 of 37 (24%) had a difference >10 mmHg and 5 of 37 (14%) had a difference >15 mmHg.
conclusionsBP obtained with Checkme correlated well with RM BP, particularly in the position (supine) in which the device was calibrated. These preliminary results are promising for conducting further research on cuffless BP measurement in the clinical and outpatient settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.