Evidence map›Paper›PMID 27147372›Full record

ArticleMedical physics2016

Novel laser-processed CsI:Tl detector for SPECT.

H Sabet, L Bläckberg, D Uzun-Ozsahin, G El-Fakhri

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
9.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 41 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Characterization or Monolithic Scintillation Detectors Etched with Laser Induced Optical Barriers.IEEE transactions on radiation and plasma medical sciences · 2019
    Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

H SabetMassachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129.
L BläckbergMassachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129 and Department of Physics and Astronomy, Uppsala University, Uppsala 75120, Sweden.
D Uzun-OzsahinMassachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129.
G El-FakhriMassachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129.
Harvard University · USMassachusetts General Hospital · USUppsala University · SE

Funding

Novel laser-processed scintillation detector for high-resolution PET scannersR21EB020162 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI SABET, HAMID · 2016 to 2017
$488k
Novel tileable scintillator-based photon counting detector for clinical X-ray CTR03EB020762 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI SABET, HAMID · 2015 to 2016
$174k
NIBIB NIH HHS R03 EB020762NIBIB NIH HHS R21 EB020162
6 · The paper itself

Abstract

purposeThe aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems.

methodsThe scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm(2) and 0.625 × 0.625 mm(2) pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments.

resultsThe process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved.

conclusionsThe results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

Indexed as

Equipment DesignFeasibility StudiesLasersTomography, Emission-Computed, Single-Photon

Identifiers

PMID27147372
PMCPMC5148208
OpenAlexW2346912352

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.