ArticleMedical physics2016
Novel laser-processed CsI:Tl detector for SPECT.
Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 41 citations in OpenAlex.
- Analytical methods for system matrix calculation and spatial resolution evaluation of DC-SPECT system.Physics in medicine and biology · 2025Article
- A look at radiation detectors and their applications in medical imaging.Japanese journal of radiology · 2024Review
- Resolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system.Biomedical physics & engineering express · 2023Article
- The clinical utilities of multi-pinhole single photon emission computed tomography.Quantitative imaging in medicine and surgery · 2020Review
- Characterization or Monolithic Scintillation Detectors Etched with Laser Induced Optical Barriers.IEEE transactions on radiation and plasma medical sciences · 2019Article
- Exploring light confinement in laser-processed LYSO:Ce for photon counting CT application.Physics in medicine and biology · 2019Article
- Light Spread Manipulation in Scintillators Using Laser Induced Optical Barriers.IEEE transactions on nuclear science · 2018Article
- An edge-readout, multilayer detector for positron emission tomography.Medical physics · 2018Article
- Simulation study of light transport in laser-processed LYSO:Ce detectors with single-side readout.Physics in medicine and biology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
Abstract
purposeThe aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems.
methodsThe scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm(2) and 0.625 × 0.625 mm(2) pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments.
resultsThe process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved.
conclusionsThe results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.