Evidence map›Paper›PMID 27147369›Full record

ArticleMedical physics2016

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS).

Junfeng Guo, Chao Wang, Kung-Sik Chan, Dakai Jin, Punam K Saha, Jered P Sieren, R G Barr, MeiLan K Han, Ella Kazerooni, Christopher B Cooper and 4 more

Registry-linked trialAbstract readMulticenter Study
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01969344 (Subpopulations and Intermediate Outcome Measures in COPD Study), which is not on this map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01969344 active not recruitingnot on this map

Subpopulations and Intermediate Outcome Measures in COPD Study

TypeobservationalSponsorUniversity of North Carolina, Chapel HillRan2010 to 2031Enrolled2,981ConditionsCOPD, Chronic Obstructive Pulmonary Disease, Chronic Bronchitis, Emphysema
3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Design of the SPIROMICS Study of Early COPD Progression: SOURCE Study.Chronic obstructive pulmonary diseases (Miami, Fla.) · 2024
    Article
  3. Article
  4. Observational
  5. Article
  6. SPIROMICS Protocol for Multicenter Quantitative Computed Tomography to Phenotype the Lungs.American journal of respiratory and critical care medicine · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Junfeng GuoDepartments of Radiology and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242.
Chao WangDepartment of Statistics and Actuarial Science, University of Iowa, Iowa City, Iowa 52242.
Kung-Sik ChanDepartment of Statistics and Actuarial Science, University of Iowa, Iowa City, Iowa 52242.
Dakai JinDepartment of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa 52242.
Punam K SahaDepartment of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa 52242.
Jered P SierenDepartment of Radiology, University of Iowa, Iowa City, Iowa 52242.
R G BarrDepartments of Medicine and Epidemiology, Columbia University Medical Center, New York, New York 10032.
MeiLan K HanDepartment of Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan 48109.
Ella KazerooniDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109.
Christopher B CooperDepartment of Medicine, University of California, Los Angeles, California 90095.
David CouperDepartment of Biostatistics, University of North Carolina, Chapel Hill, North Carolina 27599.
John D NewellDepartments of Radiology and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242.
Eric A HoffmanDepartments of Radiology, Medicine and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242.
SPIROMICS Research Group

Funding

Viral VectorP30CA086862 · NCI · UNIVERSITY OF IOWA · PI Mark E Burkard · 2000 to 2026
$70.0M
Pulmonary Toxicology Facility CoreP30ES005605 · NIEHS · UNIVERSITY OF IOWA · PI HANS-JOACHIM LEHMLER · 1990 to 2026
$40.5M
Vector Core-Core 2P30DK054759 · NIDDK · UNIVERSITY OF IOWA · PI Amy Leanne Ryan · 1998 to 2026
$30.5M
Multi-center Structural & Functional Quantitative CT Pulmonary PhenotypingR01HL112986 · NHLBI · UNIVERSITY OF IOWA · PI HOFFMAN, ERIC ALFRED · 2012 to 2016
$4.6M
Ultra-low Dose, High Speed, High Resolution, Multispectral, Multi-Source MDCT ScaS10OD018526 · OD · UNIVERSITY OF IOWA · PI HOFFMAN, ERIC ALFRED · 2015 to 2015
$2.0M
NHLBI NIH HHS HHSN268200900013CNHLBI NIH HHS HHSN268200900014CNHLBI NIH HHS HHSN268200900015CNHLBI NIH HHS HHSN268200900016CNHLBI NIH HHS HHSN268200900017CNHLBI NIH HHS HHSN268200900018CNHLBI NIH HHS HHSN268200900019CNHLBI NIH HHS HHSN268200900020CNHLBI NIH HHS R01 HL112986NIDDK NIH HHS P30 DK054759NIEHS NIH HHS P30 ES005605NIH HHS S10 OD018526
6 · The paper itself

Abstract

purposeA test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics.

methodsTwo kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline.

resultsThis study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [-6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object.

conclusionsThree operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors' results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

Indexed as

Multidetector Computed TomographyPattern Recognition, AutomatedAirData Interpretation, StatisticalLongitudinal StudiesModels, AnatomicPhantoms, ImagingQuality ControlWaterWater

Identifiers

PMID27147369
PMCPMC4851622

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.