ReviewJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2016
Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.
Review in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 34 citations in OpenAlex.
- Artificial pancreas: the past and the future.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025Review
- Effects of an artificial pancreas on postoperative inflammation in patients with esophageal cancer.BMC surgery · 2024Article
- Time course change of the insulin requirements during the perioperative period in hepatectomy and pancreatectomy by using an artificial pancreas STG-55.Diabetology international · 2023Article
- Article
- Impact of using a perioperative artificial endocrine pancreas in pancreatic resection.Annals of gastroenterological surgery · 2020Article
- The Evolving Treatment of Diabetic Retinopathy.Clinical ophthalmology (Auckland, N.Z.) · 2020Review
- Translational Research Symposium-collaborative efforts as driving forces of healthcare innovation.Journal of materials science. Materials in medicine · 2019Article
- Artificial Pancreas or Novel Beta-Cell Replacement Therapies: a Race for Optimal Glycemic Control?Current diabetes reports · 2018Review
- Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital.Diabetes care · 2018Review
- Efficacy and safety of the artificial pancreas in the paediatric population with type 1 diabetes.Journal of translational medicine · 2018Review
- Current status and issues of the artificial pancreas: abridged English translation of a special issue in Japanese.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2018Review
- Optogenerapy: When bio-electronic implant enters the modern syringe era.Porto biomedical journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.