Evidence map›Paper›PMID 27140495›Full record

ArticleNanoscale2016

Spectral triangulation: a 3D method for locating single-walled carbon nanotubes in vivo.

Ching-Wei Lin, Sergei M Bachilo, Michael Vu, Kathleen M Beckingham, R Bruce Weisman

Abstract read
In one paragraph

Article in Nanoscale, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Near-Infrared Fluorescent Single-Walled Carbon Nanotubes for Biosensing.Small (Weinheim an der Bergstrasse, Germany) · 2025
    Review
  2. Review
  3. Article
  4. Optical Voltammetry of Polymer-Encapsulated Single-Walled Carbon Nanotubes.The journal of physical chemistry. C, Nanomaterials and interfaces · 2019
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ching-Wei LinDepartment of Chemistry and the Smalley-Curl Institute, 6100 Main Street, Houston, TX 77005, USA. weisman@rice.edu.
Sergei M Bachilo
Michael Vu
Kathleen M Beckingham
R Bruce Weisman

Funding

Novel probes for expanding immunobased detection into the short wave infrared speR21CA171923 · NCI · RICE UNIVERSITY · PI BECKINGHAM, KATHLEEN MARY, WEISMAN, ROBERT BRUCE · 2012 to 2013
$372k
NCI NIH HHS R21 CA171923
6 · The paper itself

Abstract

Nanomaterials with luminescence in the short-wave infrared (SWIR) region are of special interest for biological research and medical diagnostics because of favorable tissue transparency and low autofluorescence backgrounds in that region. Single-walled carbon nanotubes (SWCNTs) show well-known sharp SWIR spectral signatures and therefore have potential for noninvasive detection and imaging of cancer tumours, when linked to selective targeting agents such as antibodies. However, such applications face the challenge of sensitively detecting and localizing the source of SWIR emission from inside tissues. A new method, called spectral triangulation, is presented for three dimensional (3D) localization using sparse optical measurements made at the specimen surface. Structurally unsorted SWCNT samples emitting over a range of wavelengths are excited inside tissue phantoms by an LED matrix. The resulting SWIR emission is sampled at points on the surface by a scanning fibre optic probe leading to an InGaAs spectrometer or a spectrally filtered InGaAs avalanche photodiode detector. Because of water absorption, attenuation of the SWCNT fluorescence in tissues is strongly wavelength-dependent. We therefore gauge the SWCNT-probe distance by analysing differential changes in the measured SWCNT emission spectra. SWCNT fluorescence can be clearly detected through at least 20 mm of tissue phantom, and the 3D locations of embedded SWCNT test samples are found with sub-millimeter accuracy at depths up to 10 mm. Our method can also distinguish and locate two embedded SWCNT sources at distinct positions.

Identifiers

PMID27140495
PMCPMC4902160

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.