Evidence map›Paper›PMID 27133454›Full record

ArticleThe Annals of thoracic surgery2016

How Local Annular Force and Collagen Density Govern Mitral Annuloplasty Ring Dehiscence Risk.

Eric L Pierce, Andrew W Siefert, Deborah M Paul, Sarah K Wells, Charles H Bloodworth, Satoshi Takebayashi, Chikashi Aoki, Morten O Jensen, Matthew J Gillespie, Robert C Gorman and 2 more

Open access · bronzeAbstract read
In one paragraph

Article in The Annals of thoracic surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
4.0field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 35 citations in OpenAlex.

  1. Mitral and tricuspid annuloplasty ring dehiscence: a systematic review with pooled analysis.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2021
    Pooled it
  2. Article
  3. Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence?European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2026
    Article
  4. Article
  5. Characterisation of global and regional mitral annular strains in an acute porcine model.Interdisciplinary cardiovascular and thoracic surgery · 2024
    Article
  6. Review
  7. Article
  8. Article
  9. Very long-term outcomes of twisted auto-pericardial mitral annuloplasty.General thoracic and cardiovascular surgery · 2020
    Article
  10. Optimized mitral annuloplasty ring design reduces loading in the posterior annulus.The Journal of thoracic and cardiovascular surgery · 2020
    Article
  11. Article
  12. Article
  13. Article
  14. Mitral annuloplasty ring suture dehiscence: In search of more robust techniques.The Journal of thoracic and cardiovascular surgery · 2016
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 1 country.

Eric L PierceThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
Andrew W SiefertThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
Deborah M PaulThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
Sarah K WellsThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
Charles H BloodworthThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
Satoshi TakebayashiGorman Cardiovascular Research Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
Chikashi AokiGorman Cardiovascular Research Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
Morten O JensenThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
Matthew J GillespieGorman Cardiovascular Research Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania.
Robert C GormanGorman Cardiovascular Research Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
Joseph H GormanGorman Cardiovascular Research Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
Ajit P YoganathanThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia. Electronic address: ajit.yoganathan@bme.gatech.edu.
Georgia Institute of Technology · USUniversity of Pennsylvania · USThe Wallace H. Coulter Department of Biomedical Engineering · US

Funding

Quantitative Force Measurements to Optimize Valve Repair for Ischemic MRR01HL113216 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI GORMAN, JOSEPH H, YOGANATHAN, AJIT P · 2013 to 2016
$2.9M
NHLBI NIH HHS R01 HL113216
6 · The paper itself

Abstract

backgroundAnnuloplasty ring dehiscence is a well described mode of mitral valve repair failure. Defining the mechanisms underlying dehiscence may facilitate its prevention.

methodsFactors that govern suture dehiscence were examined with an ovine model. After undersized ring annuloplasty in live animals (n = 5), cyclic force (FC) that acts on sutures during cardiac contraction was measured with custom transducers. FC was measured at ten suture positions, throughout cardiac cycles with peak left ventricular pressure (LVPmax) of 100, 125, and 150 mm Hg. Suture pullout testing was conducted on explanted mitral annuli (n = 12) to determine suture holding strength at each position. Finally, relative collagen density differences at suture sites around the annulus were assessed by two-photon excitation fluoroscopy.

resultsAnterior FC exceeded posterior FC at each LVPmax (eg, 2.8 ± 1.3 N versus 1.8 ± 1.2 N at LVPmax = 125 mm Hg, p < 0.01). Anterior holding strength exceeded posterior holding strength (6.4 ± 3.6 N versus 3.9 ± 1.6 N, p < 0.0001). On the basis of FC at LVPmax of 150 mm Hg, margin of safety before suture pullout was vastly higher between the trigones (exclusive) versus elsewhere (4.8 ± 0.9 N versus 1.9 ± 0.5 N, p < 0.001). Margin of safety exhibited strong correlation to collagen density (R(2) = 0.947).

conclusionsDespite lower cyclic loading on posterior sutures, the weaker posterior mitral annular tissue creates higher risk of dehiscence, apparently because of reduced collagen content. Sutures placed atop the trigones are less secure than predicted, because of a combination of reduced collagen and higher overall rigidity in this region. These findings highlight the inter-trigonal tissue as the superior anchor and have implications on the design and implantation techniques for next-generation mitral prostheses.

Indexed as

Heart Valve ProsthesisPostoperative ComplicationsSuturesAnimalsCollagenDisease Models, AnimalMitral ValveMitral Valve AnnuloplastyMitral Valve InsufficiencyProsthesis DesignSheepSuture TechniquesCollagen

Identifiers

PMID27133454
PMCPMC4958491
OpenAlexW2344755608

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.