Evidence map›Paper›PMID 27129570›Full record

ArticleSurgical endoscopy2017

Esophagogastric junction distensibility is greater following Toupet compared to Nissen fundoplication.

Reece K DeHaan, Daniel Davila, Matthew J Frelich, Jon C Gould

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 2 pooled it
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 2 syntheses or guidelines pooled it, 59 citations in OpenAlex.

  1. Use of the Functional Lumen Imaging Probe in Clinical Esophagology.The American journal of gastroenterology · 2020
    Guideline
  2. ACG Clinical Guidelines: Clinical Use of Esophageal Physiologic Testing.The American journal of gastroenterology · 2020
    Guideline
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Devices for esophageal function testing.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2022
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Reece K DeHaanDivision of General Surgery, Department of Surgery, Medical College of Wisconsin, 9200 W Wisconsin Ave, Milwaukee, WI, 53226, USA.
Daniel DavilaDivision of General Surgery, Department of Surgery, Medical College of Wisconsin, 9200 W Wisconsin Ave, Milwaukee, WI, 53226, USA.
Matthew J FrelichDivision of General Surgery, Department of Surgery, Medical College of Wisconsin, 9200 W Wisconsin Ave, Milwaukee, WI, 53226, USA.
Jon C GouldDivision of General Surgery, Department of Surgery, Medical College of Wisconsin, 9200 W Wisconsin Ave, Milwaukee, WI, 53226, USA. jgould@mcw.edu.
Medical College of Wisconsin · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe goal of antireflux surgery is to create a competent antireflux valve at the esophagogastric junction (EGJ). The two most common types of fundoplications constructed are the 360° Nissen and the 270° Toupet. We sought to determine whether there was a significant difference in distensibility at the EGJ based on fundoplication geometry (full vs. partial).

methodsThis is a retrospective review of prospective data. All subjects underwent laparoscopic fundoplication over a 47-month period for primary GERD or failed fundoplication. An endoluminal functional luminal-imaging probe (EndoFLIP

resultsA total of 75 patients underwent fundoplications during the study interval. There were 44 primary and 31 reoperative fundoplications. Nissen fundoplication was constructed in 45 and Toupet in 30. Based on the distensibility index, the EGJ distensibility significantly decreased from prior to surgery to following fundoplication in all patients. Patients undergoing reoperative antireflux surgery had an initial DI at the EGJ similar to that of patients with primary GERD. Following Toupet, the EGJ was significantly more distensible than that after Nissen fundoplication.

conclusionsLaparoscopic fundoplication results in decreased EGJ distensibility in patients with GERD. The EGJ following partial fundoplication is significantly more distensible than that after a full fundoplication.

Indexed as

ComplianceEsophagogastric JunctionFemaleFundoplicationGastroesophageal RefluxHumansLaparoscopyMaleMiddle AgedPressureReoperationRetrospective StudiesDistensibilityEndoFLIPEsophagogastric junctionFundoplicationGastroesophageal reflux disease

Identifiers

PMID27129570
OpenAlexW2343210231

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.