ArticleIEEE/SICE/RSJ International Conference on Multisensor Fusion and Integration for Intelligent Systems. IEEE/SICE/RSJ International Conference on Multisensor Fusion and Integration for Intelligent Systems2015
Force-Based Puncture Detection and Active Position Holding for Assisted Retinal Vein Cannulation.
Article in IEEE/SICE/RSJ International Conference on Multisensor Fusion and Integration for Intelligent Systems. IEEE/SICE/RSJ International Conference on Multisensor Fusion and Integration for Intelligent Systems, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 22 citations in OpenAlex.
- Comparisons of venous indwelling needles and intravenous infusion with steel needles in pediatric outpatient care.Wiener klinische Wochenschrift · 2020Trial
- Bimanual Robotic Eye Manipulation Using Adaptive Sclera Force Control: Towards Safe Retinal Vein Cannulation.IEEE transactions on medical robotics and bionics · 2025Article
- Control Modes of Teleoperated Surgical Robotic System's Tools in Ophthalmic Surgery.IEEE transactions on medical robotics and bionics · 2025Article
- Microsurgery Robots: Applications, Design, and Development.Sensors (Basel, Switzerland) · 2023Review
- Robotic Assistance for Intraocular Microsurgery: Challenges and Perspectives.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022Article
- Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation.International journal of computer assisted radiology and surgery · 2019Article
- Robot-assisted vitreoretinal surgery: current perspectives.Robotic surgery (Auckland) · 2018Article
- Admittance Control for Robot Assisted Retinal Vein Micro-Cannulation under Human-Robot Collaborative Mode.ICCAS ... : International Conference on Control, Automation, and Systems. International Conference on Control, Automation, and Systems · 2017Article
- Towards Robot-Assisted Retinal Vein Cannulation: A Motorized Force-Sensing Microneedle Integrated with a Handheld MicromanipulatorSensors (Basel, Switzerland) · 2017Article
- Robotic Vitreoretinal Surgery.Retina (Philadelphia, Pa.) · 2017Review
- Development and preliminary results of bimanual smart micro-surgical system using a ball-lens coupled OCT distance sensor.Biomedical optics express · 2016Article
- Robot-assisted retinal vein cannulation with force-based puncture detection: Micron vs. the steady-hand eye robot.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
Retinal vein cannulation is a demanding procedure proposed to treat retinal vein occlusion by direct therapeutic agent delivery methods. Challenges in identifying the moment of venous puncture, achieving cannulation and maintaining cannulation during drug delivery currently limit the feasibility of the procedure. In this study, we respond to these problems with an assistive system combining a handheld micromanipulator, Micron, with a force-sensing microneedle. The integrated system senses the instant of vein puncture based on measured forces and the position of the needle tip. The system actively holds the cannulation device securely in the vein following cannulation and during drug delivery. Preliminary testing of the system in a dry phantom, stretched vinyl membranes, demonstrates a significant improvement in the total time the needle could be maintained stably inside of the vein. This was especially evident in smaller veins and is attributed to decreased movement of the positioned cannula following venous cannulation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.