Evidence map›Paper›PMID 27123442›Full record

ArticleBioMed research international2016

Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model.

Zhe Jin, Yuheng Guan, Guibo Yu, Yu Sun

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Imaging Modalities to Assess Fracture Healing.Current osteoporosis reports · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Zhe JinDepartment of Orthopaedics, First Hospital of China Medical University, 155 Nan Jing Bei Street, Heping District, Shenyang 110001, China.
Yuheng GuanDepartment of Radiological Diagnosis and Interventional Treatment, First Hospital of China Medical University, Shenyang 110001, China.
Guibo YuDepartment of Radiological Diagnosis and Interventional Treatment, First Hospital of China Medical University, Shenyang 110001, China.
Yu SunDepartment of Orthopaedics, First Hospital of China Medical University, 155 Nan Jing Bei Street, Heping District, Shenyang 110001, China.ORCID 0000-0002-8330-942X
First Hospital of China Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background. Early radiological diagnosis and continual monitoring are of ultimate importance for timely treatment of delayed union, nonunion, and infection after bone fracture surgery. Although magnetic resonance imaging (MRI) could provide superior detailed images compared with X-ray and computed tomography (CT) without ionizing radiation, metal implants used for fracture fixation lead to abundant artifacts on MRI and thus prohibit accurate interpretation. The authors develop a novel intramedullary fixation model of rat femoral fracture using polyetheretherketone (PEEK) threaded rods and investigate its feasibility for in vivo MRI monitoring of the fracture healing process without artifact. Methods. Femoral fractures of 3 adult male Sprague-Dawley rats were fixed with intramedullary PEEK threaded rods. X-ray and MRI examinations were performed at day 7 postoperatively. Radiological images were analyzed for the existence of artifact interruption and postoperative changes in bone and peripheral soft tissue. Results. Postoperative plain film revealed no loss of reduction. MRI images illustrated the whole length of femur and peripheral tissue without artifact interruption, and the cortical bone, implanted PEEK rod, and soft tissue were clearly illustrated. Conclusion. This preliminary study introduced a novel rat model for in vivo MRI monitoring of the fracture healing process without metal artifact, by using intramedullary fixation of femur with PEEK threaded rod.

Indexed as

ArtifactsBone ScrewsAnimalsBenzophenonesDisease Models, AnimalEquipment Failure AnalysisFemoral FracturesFracture Fixation, InternalImage EnhancementKetonesMagnetic Resonance ImagingMaleMetalsPolyethylene GlycolsPolymersPostoperative CareBenzophenonesKetonesMetalspolyetheretherketonePolyethylene GlycolsPolymers

Identifiers

PMID27123442
PMCPMC4830717
OpenAlexW2319882859

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.