ArticleEar and hearing
Benefits to Speech Perception in Noise From the Binaural Integration of Electric and Acoustic Signals in Simulated Unilateral Deafness.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 31 citations in OpenAlex.
- Bilateral gene therapy in children with autosomal recessive deafness 9: single-arm trial results.Nature medicine · 2024Trial
- Effects of Cochlear Implantation on Binaural Hearing in Adults With Unilateral Hearing Loss.Trends in hearingTrial
- Re-administration of AAV-mediated gene therapy for OTOF-related deafness: a single-arm trial.Nature medicine · 2026Article
- Exploring AAV-Mediated Gene Therapy for Inner Ear Diseases: from Preclinical Success to Clinical Potential.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Review
- Reduced Cochlear Implant Performance in Listeners with Single-Sided Deafness: Comparison with Bilateral Listeners.Journal of the Association for Research in Otolaryngology : JARO · 2025Article
- Differences in consonant confusion patterns between bimodal cochlear implant users with greater and less bimodal advantage.Frontiers in psychology · 2025Article
- Cortical mechanisms of across-ear speech integration investigated using functional near-infrared spectroscopy (fNIRS).PloS one · 2024Article
- Matching the pitch perception of the cochlear implanted ear with the contralateral ear in patients with single-sided deafness: a novel approach.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023Article
- Effect of Realistic Test Conditions on Perception of Speech, Music, and Binaural Cues in Normal-Hearing Listeners.American journal of audiology · 2023Article
- Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise.Audiology & neuro-otology · 2023Article
- Frequency Fitting Optimization Using Evolutionary Algorithm in Cochlear Implant Users with Bimodal Binaural Hearing.Brain sciences · 2022Article
- Cochlear Implant and Hearing Aid: Objective Measures of Binaural Benefit.Frontiers in neuroscience · 2020Article
- Enhancement of Consonant Recognition in Bimodal and Normal Hearing Listeners.The Annals of otology, rhinology, and laryngology · 2019Article
- Interaural Time Difference Perception with a Cochlear Implant and a Normal Ear.Journal of the Association for Research in Otolaryngology : JARO · 2018Article
- An automated A-value measurement tool for accurate cochlear duct length estimation.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2018Article
- Article
- Targeted Auditory Rehabilitation Employing Direct Audio Input in Children With Single-Sided Deafness Using a Cochlear Implant.Ear and hearingArticle
- Searching for the Sound of a Cochlear Implant: Evaluation of Different Vocoder Parameters by Cochlear Implant Users With Single-Sided Deafness.Trends in hearingArticle
- Article
- Interaural Time-Difference Discrimination as a Measure of Place of Stimulation for Cochlear-Implant Users With Single-Sided Deafness.Trends in hearingArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
objectivesThis study used vocoder simulations with normal-hearing (NH) listeners to (1) measure their ability to integrate speech information from an NH ear and a simulated cochlear implant (CI), and (2) investigate whether binaural integration is disrupted by a mismatch in the delivery of spectral information between the ears arising from a misalignment in the mapping of frequency to place.
designEight NH volunteers participated in the study and listened to sentences embedded in background noise via headphones. Stimuli presented to the left ear were unprocessed. Stimuli presented to the right ear (referred to as the CI-simulation ear) were processed using an eight-channel noise vocoder with one of the three processing strategies. An Ideal strategy simulated a frequency-to-place map across all channels that matched the delivery of spectral information between the ears. A Realistic strategy created a misalignment in the mapping of frequency to place in the CI-simulation ear where the size of the mismatch between the ears varied across channels. Finally, a Shifted strategy imposed a similar degree of misalignment in all channels, resulting in consistent mismatch between the ears across frequency. The ability to report key words in sentences was assessed under monaural and binaural listening conditions and at signal to noise ratios (SNRs) established by estimating speech-reception thresholds in each ear alone. The SNRs ensured that the monaural performance of the left ear never exceeded that of the CI-simulation ear. The advantages of binaural integration were calculated by comparing binaural performance with monaural performance using the CI-simulation ear alone. Thus, these advantages reflected the additional use of the experimentally constrained left ear and were not attributable to better-ear listening.
resultsBinaural performance was as accurate as, or more accurate than, monaural performance with the CI-simulation ear alone. When both ears supported a similar level of monaural performance (50%), binaural integration advantages were found regardless of whether a mismatch was simulated or not. When the CI-simulation ear supported a superior level of monaural performance (71%), evidence of binaural integration was absent when a mismatch was simulated using both the Realistic and the Ideal processing strategies. This absence of integration could not be accounted for by ceiling effects or by changes in SNR.
conclusionsIf generalizable to unilaterally deaf CI users, the results of the current simulation study would suggest that benefits to speech perception in noise can be obtained by integrating information from an implanted ear and an NH ear. A mismatch in the delivery of spectral information between the ears due to a misalignment in the mapping of frequency to place may disrupt binaural integration in situations where both ears cannot support a similar level of monaural speech understanding. Previous studies that have measured the speech perception of unilaterally deaf individuals after CI but with nonindividualized frequency-to-electrode allocations may therefore have underestimated the potential benefits of providing binaural hearing. However, it remains unclear whether the size and nature of the potential incremental benefits from individualized allocations are sufficient to justify the time and resources required to derive them based on cochlear imaging or pitch-matching tasks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.