Evidence map›Paper›PMID 27110431›Full record

ArticleProceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems

Effects of Micro-Vibratory Modulation during Robot-Assisted Membrane Peeling.

Berk Gonenc, Peter Gehlbach, Russell H Taylor, Iulian Iordachita

Abstract read
In one paragraph

Article in Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Robot-assisted retinal vein cannulation with force-based puncture detection: Micron vs. the steady-hand eye robot.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Berk GonencCISST ERC at Johns Hopkins University, Baltimore, MD 21218 USA.
Peter GehlbachWilmer Eye Institute at The Johns Hopkins School of Medicine, Baltimore, MD 21287 USA ( pgelbach@jhmi.edu ).
Russell H TaylorCISST ERC at Johns Hopkins University, Baltimore, MD 21218 USA ( rht@jhu.edu ).
Iulian IordachitaCISST ERC at Johns Hopkins University, Baltimore, MD 21218 USA ( iordachita@jhu.edu ).

Funding

A Microsurgical Assistant SystemR01EB007969 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI TAYLOR, RUSSELL H · 2008 to 2012
$5.7M
An Active Handheld MicromanipulatorR01EB000526 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI RIVIERE, CAMERON N · 2003 to 2017
$2.6M
NIBIB NIH HHS R01 EB000526NIBIB NIH HHS R01 EB007969
6 · The paper itself

Abstract

In retinal microsurgery, membrane peeling is a standard procedure requiring the delamination of a thin fibrous membrane adherent to the retina surface by applying very small forces. Robotic devices with combined force-sensing instruments have significant potential to assist this procedure by facilitating membrane delamination through induced micro-vibrations. However, defining the optimal frequency and amplitude for generating such vibrations, and updating these parameters during the procedure is not trivial. Automatic adjustment of these parameters via an adaptive control scheme is possible only if the individual parameter effects on delamination behavior are known. This study presents an experimental exploration of how micro-vibration amplitude and frequency affect membrane peeling forces alone. Combining a micromanipulator and a force-sensing micro-forceps, several peeling experiments were done on artificial phantoms (bandages) and inner shell membrane of raw chicken eggs. In the tested range of micro-vibration frequencies (10-50 Hz) the average delamination force was minimized mostly at 30 Hz for the bandages and at 50 Hz for the egg membranes. Increasing the micro-vibration amplitude from 50 μm up to 150 μm provided further reduction in average force, thus facilitated membrane delamination.

Identifiers

PMID27110431
PMCPMC4838409

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.