Evidence map›Paper›PMID 27110338›Full record

ArticleIranian journal of radiology : a quarterly journal published by the Iranian Radiological Society2016

Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography.

Jung-Su Kim, Sang-Wook Yoon, Deok-Nam Seo, So-Ra Nam, Jung-Min Kim

Open access · hybridAbstract read
In one paragraph

Article in Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jung-Su KimDepartment of Radiologic Science, College of Health Science, Korea University, Seoul, South Korea.
Sang-Wook YoonDepartment of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Gyeonggi-do, South Korea.
Deok-Nam SeoDepartment of Radiologic Science, College of Health Science, Korea University, Seoul, South Korea.
So-Ra NamDepartment of Radiologic Science, College of Health Science, Korea University, Seoul, South Korea.
Jung-Min KimDepartment of Radiologic Science, College of Health Science, Korea University, Seoul, South Korea.
Korea University · KRCHA University Bundang Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhole spine scanography (WSS) is a radiologic examination that requires whole body X-ray exposure. Consequently, the amount of patient radiation exposure is higher than the radiation dose following routine X-ray examination.

objectivesSeveral studies have evaluated the patient effective dose (ED) following single exposure film-screen WSS. The objective of this study was to evaluate patient ED during WSS, based on the automatic image pasting method for multiple exposure digital radiography (APMDR). Further, the calculated EDs were compared with the results of previous studies involving single exposure film-screen WSS. PATIENTS AND

methodsWe evaluated the ED of 50 consecutive patients (M:F = 28:22) who underwent WSS using APMDR. The anterior-posterior (AP) and lateral (LAT) projection EDs were evaluated based on the Monte Carlo simulation.

resultsUsing APMDR, the mean number of exposures was 6.1 for AP and 6.5 for LAT projections. LAT projections required more exposures (6.55%) than AP projections. The mean ED was 0.6276 mSv (AP) and 0.6716 mSv (LAT). The mean ED for LAT projections was 0.6061 mSv in automatic exposure control (AEC) and 0.7694 mSv in manual mode. The relationship between dose-area-product (DAP) and ED revealed a proportional correlation (AP, R(2) = 0.943; LAT, R(2) = 0.773). Compared to prior research involving single exposure screen-film WSS, the patient ED following WSS using APMDR was lower on AP than on LAT projections.

conclusionDespite multiple exposures, ED control is more effective if WSS is performed using APMDR in the AEC mode.

Indexed as

Health PhysicsRadiation DosageX-Rays

Identifiers

PMID27110338
PMCPMC4835671
OpenAlexW2194195022

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.