ArticleIranian journal of radiology : a quarterly journal published by the Iranian Radiological Society2016
Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography.
Article in Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 5 citations in OpenAlex.
- A new 3D full-body scanner analyzing the sagittal and coronal balance of the adult spine: a preliminary prospective observational study.Acta neurochirurgica · 2025Observational
- Deep learning-based fully automatic Risser stage assessment model using abdominal radiographs.Pediatric radiology · 2024Article
- Usefulness of an Additional Filter Created Using 3D Printing for Whole-Body X-ray Imaging with a Long-Length Detector.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWhole spine scanography (WSS) is a radiologic examination that requires whole body X-ray exposure. Consequently, the amount of patient radiation exposure is higher than the radiation dose following routine X-ray examination.
objectivesSeveral studies have evaluated the patient effective dose (ED) following single exposure film-screen WSS. The objective of this study was to evaluate patient ED during WSS, based on the automatic image pasting method for multiple exposure digital radiography (APMDR). Further, the calculated EDs were compared with the results of previous studies involving single exposure film-screen WSS. PATIENTS AND
methodsWe evaluated the ED of 50 consecutive patients (M:F = 28:22) who underwent WSS using APMDR. The anterior-posterior (AP) and lateral (LAT) projection EDs were evaluated based on the Monte Carlo simulation.
resultsUsing APMDR, the mean number of exposures was 6.1 for AP and 6.5 for LAT projections. LAT projections required more exposures (6.55%) than AP projections. The mean ED was 0.6276 mSv (AP) and 0.6716 mSv (LAT). The mean ED for LAT projections was 0.6061 mSv in automatic exposure control (AEC) and 0.7694 mSv in manual mode. The relationship between dose-area-product (DAP) and ED revealed a proportional correlation (AP, R(2) = 0.943; LAT, R(2) = 0.773). Compared to prior research involving single exposure screen-film WSS, the patient ED following WSS using APMDR was lower on AP than on LAT projections.
conclusionDespite multiple exposures, ED control is more effective if WSS is performed using APMDR in the AEC mode.