ArticleMagma (New York, N.Y.)2016
The traveling heads: multicenter brain imaging at 7 Tesla.
Article in Magma (New York, N.Y.), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.Magnetic resonance in medicine · 2026Article
- Comparison of commercial 1Tx32Rx vs. 8Tx32Rx head coils for routine 7T neuroimaging.Frontiers in neuroimaging · 2026Article
- Seminars in epileptology: Presurgical epilepsy evaluation.Epileptic disorders : international epilepsy journal with videotape · 2025Review
- Multi-center QA of ultrahigh-field systems.Magma (New York, N.Y.) · 2025Review
- Pooled analysis of multiple sclerosis findings on multisite 7 Tesla MRI: Protocol and initial observations.Human brain mapping · 2024Article
- The use of 7T MRI in multiple sclerosis: review and consensus statement from the North American Imaging in Multiple Sclerosis Cooperative.Brain communications · 2024Review
- Traveling Subject-Informed Harmonization Increases Reliability of Brain Diffusion Tensor and Neurite Mapping.Aging and disease · 2023Article
- Germany's journey toward 14 Tesla human magnetic resonance.Magma (New York, N.Y.) · 2023Review
- Multisite MRI reproducibility of lateral ventricular volume using the NAIMS cooperative pilot dataset.Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2022Article
- Development and evaluation of a numerical simulation approach to predict metal artifacts from passive implants in MRI.Magma (New York, N.Y.) · 2022Article
- Lifespan Volume Trajectories From Non-harmonized T1-Weighted MRI Do Not Differ After Site Correction Based on Traveling Human Phantoms.Frontiers in neurology · 2022Article
- Assessment of myelination in infants and young children by T1 relaxation time measurements using the magnetization-prepared 2 rapid acquisition gradient echoes sequence.Pediatric radiology · 2021Article
- Quantitative magnetic resonance imaging towards clinical application in multiple sclerosis.Brain : a journal of neurology · 2021Review
- Review
- European Ultrahigh-Field Imaging Network for Neurodegenerative Diseases (EUFIND).Alzheimer's & dementia (Amsterdam, Netherlands) · 2019Article
- Effects of aging on T₁, T₂*, and QSM MRI values in the subcortex.Brain structure & function · 2017Article
- 7T-guided super-resolution of 3T MRI.Medical physics · 2017Article
- From ultrahigh to extreme field magnetic resonance: where physics, biology and medicine meet.Magma (New York, N.Y.) · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThis study evaluates the inter-site and intra-site reproducibility of 7 Tesla brain imaging and compares it to literature values for other field strengths. MATERIALS AND
methodsThe same two subjects were imaged at eight different 7 T sites. MP2RAGE, TSE, TOF, SWI, EPI as well as B1 and B0 field maps were analyzed quantitatively to assess inter-site reproducibility. Intra-site reproducibility was measured with rescans at three sites.
resultsQuantitative measures of MP2RAGE scans showed high agreement. Inter-site and intra-site reproducibility errors were comparable to 1.5 and 3 T. Other sequences also showed high reproducibility between the sites, but differences were also revealed. The different RF coils used were the main source for systematic differences between the sites.
conclusionOur results show for the first time that multi-center brain imaging studies of the supratentorial brain can be performed at 7 T with high reproducibility and similar reliability as at 3T. This study develops the basis for future large-scale 7 T multi-site studies.
Indexed as
Identifiers
27097904What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.