Evidence map›Paper›PMID 27095484›Full record

ArticleActa biomaterialia2016

Improved hemocompatibility of silicone rubber extracorporeal tubing via solvent swelling-impregnation of S-nitroso-N-acetylpenicillamine (SNAP) and evaluation in rabbit thrombogenicity model.

Elizabeth J Brisbois, Terry C Major, Marcus J Goudie, Robert H Bartlett, Mark E Meyerhoff, Hitesh Handa

Abstract read
In one paragraph

Article in Acta biomaterialia, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 53 papers.

0numbers the graph read from it
0cells of the map it votes in
53citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

53 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Anti-biofouling organogel and substrate independent coatings with a continuous lubricating network.Chemical engineering journal (Lausanne, Switzerland : 1996) · 2025
    Article
  7. Article
  8. Article
  9. Antithrombotic and Antimicrobial Potential of S -Nitroso-1-Adamantanethiol-Impregnated Extracorporeal Circuit.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025
    Article
  10. Article
  11. Wearable nitric oxide-releasing antibacterial insert for preventing device-associated infections.Journal of controlled release : official journal of the Controlled Release Society · 2024
    Article
  12. Article
  13. Review
  14. Article
  15. PreventingACS applied bio materials · 2024
    Article
  16. Article
  17. Review
  18. Current knowledge gaps in extracorporeal respiratory support.Intensive care medicine experimental · 2023
    Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Elizabeth J BrisboisDepartment of Surgery, University of Michigan, Ann Arbor, MI, USA.
Terry C MajorDepartment of Surgery, University of Michigan, Ann Arbor, MI, USA.
Marcus J GoudieDepartment of Biological Engineering, University of Georgia, Athens, GA, USA.
Robert H BartlettDepartment of Surgery, University of Michigan, Ann Arbor, MI, USA.
Mark E MeyerhoffDepartment of Chemistry, University of Michigan, Ann Arbor, MI, USA.
Hitesh HandaDepartment of Biological Engineering, University of Georgia, Athens, GA, USA. Electronic address: hhanda@uga.edu.

Funding

Biocompatible Chemical Sensors Via Nitric Oxide Release/GenerationR01EB000783 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI MEYERHOFF, MARK E · 2002 to 2013
$3.1M
Thromboresistant Polymers Via Catalytic Generation of NOR01EB004527 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI MEYERHOFF, MARK E · 2005 to 2012
$2.4M
Prevention of Thrombosis by NO Secreting PolymersK25HL111213 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI HANDA, HITESH · 2012 to 2016
$739k
NHLBI NIH HHS K25 HL111213NIBIB NIH HHS R01 EB000783NIBIB NIH HHS R01 EB004527
6 · The paper itself

Abstract

unlabelledBlood-contacting devices, including extracorporeal circulation (ECC) circuits, can suffer from complications due to platelet activation and thrombus formation. Development of nitric oxide (NO) releasing polymers is one method to improve hemocompatibility, taking advantage of the ability of low levels of NO to prevent platelet activation/adhesion. In this study a novel solvent swelling method is used to load the walls of silicone rubber tubing with the NO donor S-nitroso-N-acetylpenicillamine (SNAP). This SNAP-silicone rubber tubing exhibits an NO flux of ca. 1×10(-10)molcm(-2)min(-1), which mimics the range of NO release from the normal endothelium, which is stable for at least 4h. Images of the tubing before and after swelling, obtained via scanning electron microscopy, demonstrate that this swelling method has little effect on the surface properties of the tubing. The SNAP-loaded silicone rubber and silicone rubber control tubing are used to fabricate ECC circuits that are evaluated in a rabbit model of thrombogenicity. After 4h of blood flow, the SNAP-loaded silicone rubber circuits were able to preserve the blood platelet count at 64% of baseline (vs. 12% for silicone rubber control). A 67% reduction in the degree of thrombus formation within the thrombogenicity chamber was also observed. This study demonstrates the ability to improve the hemocompatibility of existing/commercial silicone rubber tubing via a simple solvent swelling-impregnation technique, which may also be applicable to other silicone-based blood-contacting devices. STATEMENT OF SIGNIFICANCE: Localized nitric oxide (NO) release can be achieved from biomedical grade polymers doped with S-nitroso-N-acetylpenicillamine (SNAP). Despite the promising in vitro and in vivo biocompatibility results reported for these NO releasing polymers, many of these materials may face challenges in being translated to clinical applications, especially in the areas of polymer processing and manufacturing. In this study, we report a solvent swelling-impregnation technique to incorporate SNAP into extracorporeal circuit (ECC) tubing. These NO-releasing ECCs were able to attenuate the activation of platelets and maintain their functionality, while significantly reducing the extent of thrombus formation during 4h blood flow in the rabbit model of thrombogenicity.

Indexed as

AnimalsBlood PlateletsDisease Models, AnimalExtracorporeal CirculationHemodynamicsMaterials TestingMicroscopy, Electron, ScanningNitric OxideRabbitsSilicone ElastomersS-Nitroso-N-AcetylpenicillamineSolventsThrombosisTime FactorsNitric OxideSilicone ElastomersS-Nitroso-N-AcetylpenicillamineSolventsBlood compatibilityExtracorporeal circulationNitric oxide deliveryS-NitrosothiolsThrombosis

Identifiers

PMID27095484
PMCPMC4870167

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.